− 44 −
7.5
Thrust Control
Current-limiting value is established to control heat generation from the motor.
Use under the following condition:
duty comparison{operating time/(operating time + standby time) x 100 [%]}=50% or less.
Refer to Section 4.2 e) along with this section for thrust control setting.
7.5.1
General Transfer Movement
It will move with the power necessary for operation (current-limiting value: 100% maximum) during
transfer.
CAUTION:
※1: There are occasions where setting speed is not reached depending on stroke length and acceleration.
※2: If it becomes inoperable at 100% current-limiting value (for reasons such as overlarge external force)
during operation, it will be detected as overloaded, an alarm will output, and it will stop.
※3: Refer to Section 7.4 for Retaining Force.
Speed
Thrust
Thrust Control of General Transfer Movement
Max:100%
(※2)
Retaining
Force(※3)
Standby
(Speed =0)
Setting
Speed(※1)
General Transfer
Movement
time
Movement
Starting
Position
target
position
Position
Completion
Output
ON
OFF
Displacement
time
time
time