![CKD ELCR Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/ckd/elcr-series/elcr-series_instruction-manual_2611699030.webp)
<SM-431049>
− 29 −
b)
Output Circuit
Example of a connection:
CAUTION:
・
External power supply (24VDC) is necessary for both input and output.
・
For input and output COM, either of + or −can be used
Output Specifications
Items
Specifications
No. of Output Points
(Circuit)
7point
Load Voltage
(V)
DC24V±10%
Load Current
(mA)
10mA or less
/1point
Maximum Current
(mA)
70mA
Maximum Consumption
Current (mA)※1
91mA
Internal Voltage Drop
6V or less
(at 25℃ or below)※2
Leakage Current
10μA
Output Short-Circuit
Protection Circuit
With
Connecting Load
PLC
※1 Maximum Consumption Current is the value including
input circuit.
※2
At 40
℃
, load current becomes 6V or less at 9mA
Output 1
Output
COM
Product Output Circuit
Host System Input Circuit
Input
Output 2
Output 7
COM(-)
External power
supply (DC24V)
When Output COM is "+"
+
-
Input
Input
Host System Input Circuit
COM(+)
When Output COM is "-"
・・
・
+
-
Product Output Circuit
External power
supply (DC24V)
Output 1
Output 2
Output 7
Input
Input
Input
Output
COM
Output
COM
Output Circuit
Output is non-polar.
(For output COM, either of + or −can be used.)