f) Input/Output Signals in Solenoid Valve Mode
[Input Signal Status and Control Descriptions in Solenoid Valve Mode]
0:OFF(Level Input)、1:ON(Level Input)、0↓:Rise Input、1↑:Fall Input
any:Status(0、1、0↓、1↑)
Input
Signal
Input 1
Input 2
Input 3、4
Input 5
Input 6
Input 7
Control Descriptions
Function
Universal
Input
Universal
Input
Universal
Input
Return-to
-Origin
Emergency
Stop ※1
Alarm Reset
any
any
any
any
0
any
Emergency Stop
any
any
any
any
1
any
Emergency Stop Cancellation
(0↓)※2
0↓※2
(0↓)※2
1↑※3
1
any
Return-to-Origin
any
any
any
any
1
1↑
Alarm Reset
any
0
any
0/1
1
any
Move to 1st point
any
1
any
0/1
1
any
Move to 2nd point
0
0
any
0/1
1
any
Maintain last input conditions
1↑
0
any
0/1
1
any
Move to 1st point
0
1↑
any
0/1
1
any
Move to 2nd point
1
1
any
0/1
1
any
Maintain last input conditions
0
0
any
0/1
1
any
Stop at that spot
1
0
any
0/1
1
any
Move to 1st point
0
1
any
0/1
1
any
Move to 2nd point
1
1
any
0/1
1
any
Maintain last input conditions
※1.Emergency stop has b-contact connection.
※2.Valid only when origin has not been detected after turning on power.
(If it becomes “1” during operation, it will stop at that spot.)
※3.Return-to-origin is rejected during the movement. (If it becomes “0↓” during operation, it will stop at that spot.)
[Output Signal Status and Output Descriptions in Solenoid Valve Mode]
0:OFF(Level Output)、1:ON(Level Output)
any:Status(0、1)
Output
Signal
Output 1
Output 2
Output 3、4
Output 5
Output 6
Output 7
Output Descriptions
Function
Positioning
Completion 1
Output
Positioning
Completion 2
Output
Unused
Return-to-
Origin
Completion
Signal
Ready-to-
Operate
Signal ※1
Alarm Signal
※2
any
any
any
1
1
1
Waiting for PLC Input
0
0
any
0
0
1
Origin Detection Incomplete
any
any
any
any
0
0
Alarm
any
any
any
any
0
1
Emergency Stop Input
1
0
any
1
1
1
Move to 1st point complete
0
1
any
1
1
1
Move to 2nd point complete
1
0
any
1
1
1
Move to 1st point complete
0
1
any
1
1
1
Move to 2nd point complete
0
0
any
1
1
1
Stop at that spot
1
0
any
1
1
1
Move to 1st point complete
0
1
any
1
1
1
Move to 2nd point complete
※1.If input from PLC is rejected when the teaching box is connected, it becomes 0 output.
※2.Alarms have b-contact connection; other outputs have a-contact connections.