The range is from -11.5dBm to -1.5dBm for ONS-CFP2-WDM,-11.5dBm to -1.5dBm for ONS-CFP2-WDM-1KL and
-8dBm to 2dBm for ONS-CFP2-WDM-1KE PID types. The PID information can be obtained from inventory details
using show inventory command.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447)
UNC-WORD Alarm
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
Logical Objects: TRUNK
The Uncorrected FEC Word condition indicates that the FEC capability cannot correct the frame.
Clear the UNC-WORD Alarm
Step 1
Ensure that the fiber connector for the card is completely plugged in.
Step 2
Ensure that the ports on the far end and near end nodes have the same port rates and FEC settings.
Step 3
If the BER threshold is correct and at the expected level, use an optical test set to measure the power level of the line to
ensure it is within guidelines. For specific procedures to use the test set equipment, consult the manufacturer.
Step 4
If the optical power level is good, verify that the optical receive levels are within the acceptable range.
Step 5
If receive levels are good, clean the fibers at both ends.
Step 6
If the condition does not clear, verify that a single-mode fiber is used.
Step 7
Verify if the fiber is of single-mode type.
Step 8
Clean the fiber connectors at both ends for a signal degrade.
Step 9
If the problem does not clear, the transmitter at the other end of the optical line could be failing and requires replacement.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
UPPER-CTRL-FPGA-PCIE-ERROR Alarm
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Objects: EQUIPMENT
The UPPER-CTRL-FPGA-PCIE-ERROR alarm is raised when a control FPGA of the upper board is
unreachable because of a Peripheral Component Interconnect Express (PCIe) error.
Clear the UPPER-CTRL-FPGA-PCIE-ERROR Alarm
If the alarm does not clear it indicates that it is a hardware fault.
Troubleshooting Guide for Cisco NCS 1002, IOS XR Release 6.3.x
72
Alarm Troubleshooting
UNC-WORD Alarm
Содержание NCS 1002
Страница 4: ......
Страница 10: ...Troubleshooting Guide for Cisco NCS 1002 IOS XR Release 6 3 x x Contents ...