HI-RXPOWER Alarm
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Equipment High Receive Power (HI-RXPOWER) alarm is an indicator of the received optical signal
power of NCS 1002. This alarm occurs on the client optics controller when the measured individual lane
optical signal power of the received signal exceeds the default or user-defined threshold. This alarm occurs
on the trunk optics controller when the total optical signal power of the received signal exceeds the default
or user-defined threshold. You can configure the threshold value using the
controller optics R/S/I/P
rx-high-threshold
command in the config mode.
Clear the HI-RXPOWER Alarm
Step 1
Verify the value of the high receive power threshold of the NCS 1002 using the
show controller optics R/S/I/P
command.
Step 2
If the value is not within the high receive power threshold range, configure the high receive power threshold using the
controller optics R/S/I/P rx-high-threshold
command in the config mode. The range is from -400 to 300 dBm (in units
of 0.1 dBm).
Step 3
If the value is within the range of the high receive power threshold, physically verify, by using a standard power meter
that the optical input power is overcoming the expected power threshold.
Step 4
Change the threshold value or use an attenuator to reduce the input power to the desired level.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
HI-TXPOWER Alarm
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Equipment High Transmit Power (HI-TXPOWER) alarm is an indicator of the transmitted optical signal
power of NCS 1002. This alarm occurs on the client optics controller when the measured individual lane
optical signal power of the transmitted signal exceeds the default or user-defined threshold. This alarm occurs
on the trunk optics controller when the total optical signal power of the transmitted signal exceeds the default
or user-defined threshold. You can configure the threshold value using the
controller optics R/S/I/P
tx-high-threshold
command in the config mode.
Clear the HI-TXPOWER Alarm
Step 1
Verify the value of the high transmit power threshold of NCS 1002 using the
show controller optics R/S/I/P
command.
Step 2
If the value is not within the high transmit power threshold range, configure the high transmit power threshold using the
controller optics R/S/I/P tx-high-threshold
command in the config mode. The range is from -400 to 300 dBm (in units
of 0.1 dBm).