Clear the FAN FAIL Alarm
Verify that a fan is correctly inserted. The fan should run immediately when correctly inserted.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.
FAN MISSING Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: FT
The FAN MISSING alarm is raised on the NCS 1002 when one of the three fans is missing or is not correctly
inserted. When any fan is missing, the temperature of the NCS 1002 can rise above its normal operating
range. This condition can trigger the TEMP THRESHOLD alarm.
Clear the FAN MISSING Alarm
Step 1
Verify that a fan is missing or is not correctly inserted.
Step 2
Insert a fan. The fan should run immediately when correctly inserted.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.
FAN-TRAY-INSERT Alarm
Default Severity: Minor(MN), Non-Service Affecting (NSA)
Logical Objects: FT
The FAN-TRAY-INSERT alarm is raised on the NCS 1002 when the fan tray is detected in the chassis.
Clear the FAN-TRAY-INSERT Alarm
This alarm clears automatically.
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
Troubleshooting Guide for Cisco NCS 1002, IOS XR Release 6.3.x
50
Alarm Troubleshooting
Clear the FAN FAIL Alarm