PSU INSERTED Alarm
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: PSU
The PSU INSERTED alarm is raised on the NCS 1002 when a power supply is inserted to the device.
Clear the PSU INSERTED Alarm
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or call Cisco TAC (1 800 553-2447).
PSU REDUNDANCY LOST Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: PSU
The PSU REDUNDANCY LOST alarm is raised on the NCS 1002 when a power supply is removed.
Clear the PSU REDUNDANCY LOST Alarm
The alarm clears when a power supply is inserted on the NCS 1002
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.
REMOTE-FAULT Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: CLIENT
The REMOTE-FAULT alarm is raised on the NCS 1002 when a remote fault character sequence is received
in the incoming MAC stream as defined in IEEE 802.3.
Clear the REMOTE-FAULT Alarm
Step 1
Verify and resolve the client port fault and remote fault errors on the remote or upstream node.
Step 2
Verify and resolve loss of signal synchronization error on the remote or upstream node.
Troubleshooting Guide for Cisco NCS 1002, IOS XR Release 6.3.x
67
Alarm Troubleshooting