The POWER MODULE OUTPUT DISABLED alarm is raised on the NCS 1002 when the power supply is
disabled on the active PEM.
Clear the POWER MODULE OUTPUT DISABLED Alarm
This alarm clears when the power supply is enabled.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free
Technical Support numbers for your country.
PEM-PWR-TRAY-LVL-RED-LOST
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: PEM
The PEM-PWR-TRAY-LVL-RED-LOST alarm is raised on the NCS 1002 when one of the two active PEMs
is removed.
Clear the PEM-PWR-TRAY-LVL-RED-LOST Alarm
This alarm clears when you insert a power supply on the chassis.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free
Technical Support numbers for your country.
PLL-FAIL-SLICE Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: SLICE
The PLL-FAIL-SLICE alarm is raised on the slice when a fault is detected in the Phase Lock Loop (PLL)
device and it becomes inaccessible.
Clear the PLL-FAIL-SLICE Alarm
Remove the slice configuration and reload the Cisco IOS XR.
If the alarm does not clear it indicates that it is a hardware fault.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.