Clear the MKA-START-FAIL-MISSING-PSK Alarm
The alarm clears after configuring the lifetime of the key to current active key and bringing up the mks session.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free
Technical Support numbers for your country.
MKA-UNSECURE-MISSING-PSK Alarm
Default Severity: Critical (CR) , Service-Affecting (SA)
Logical Objects: Client
The MACsec Key Agreement-UNSECURE-MISSING-Pre-Shared-Keys alarm is raised, when the existing
secured MKA session is brought down. This is due to the insecurity caused by the non-active keys present in
the keychain on the NCS 1002 interface.
Clear the MKA-UNSECURE-MISSING-PSK Alarm
The alarm clears after configuring an active key in the keychain for bringing up the mka session. It is also
required to have overlapping keys, so that the next key becomes active prior to the expiry of existing key.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical
Support Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
http://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free
Technical Support numbers for your country.
MORE-THAN-ONE-FAN-TRAY-REMOVED Alarm
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Objects: EQUIPMENT
The MORE-THAN-ONE-FAN-TRAY-REMOVED alarm occurs when more than one fan tray is removed
from the chassis.
Clear the MORE-THAN-ONE-FAN-TRAY-REMOVED Alarm
Ensure that all the three fans are inserted and are functioning properly.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
for more information or log into
en/us/support/web/tsd-cisco-worldwide-contacts.html
to obtain a directory of toll-free Technical Support numbers for
your country.
NM-I2C-ACCESS-ERROR Alarm
Default Severity: Major (MJ), Service Affecting (SA)
Troubleshooting Guide for Cisco NCS 1002, IOS XR Release 6.3.x
59
Alarm Troubleshooting
Clear the MKA-START-FAIL-MISSING-PSK Alarm
Содержание NCS 1002
Страница 4: ......
Страница 10: ...Troubleshooting Guide for Cisco NCS 1002 IOS XR Release 6 3 x x Contents ...