• Fan not detected
• Fan speed problem
• Power module fails
• Power module not detected
• Temperature of the device exceeds a threshold value
• Voltage of the device exceeds a threshold value
Step 1
admin
Enters system admin EXEC mode.
Example:
RP/0/RP0/CPU0:ios#
admin
Step 2
show environment
[
all
|
fan
|
power
|
voltages
|
current
|
temperatures
] [
location
|
location
]
Displays the environmental parameters of the NCS 1002.
Example:
The following example shows sample output from the
show environment
command with the
fan
keyword.
sysadmin-vm:0_RP0#
show environment fan
Wed Nov
11 02:04:58.161 UTC
=====================================
Fan speed (rpm)
Location
FRU Type
FAN_0
-------------------------------------
0/FT0
NCS1K-FTA
4800
0/FT1
NCS1K-FTA
4800
0/FT2
NCS1K-FTA
4680
0/PM1
NCS1K-2KW-AC
8064
The table below lists the temperature threshold values for the different fan speeds.
Falling Min
Temperature (°C)
Falling Max
Temperature (°C)
Rising Max
Temperature (°C)
Rising Min
Temperature (°C)
Fan speed (rpm)
-127
27
28
-127
4800
28
29
30
29
5500
30
35
36
31
8500
36
40
41
37
10500
41
43
44
42
12500
44
127
127
45
14500
The following example shows sample output from the
show environment
command with the
temperatures
keyword.