5-10
Cisco 1120 Connected Grid Router Hardware Installation Guide
OL-26438-02
Chapter 5 Connecting the Router to Power
Power Cycling the Router
Step 4
After the wires are inserted in the terminal block, use the screwdriver to tighten the terminal block wire
screws to keep the wires in place. The screws are shown in
Figure 5-2
.
Step 5
Taking care not to place strain on the wires, insert the terminal block into the mating connector on the
router. The mating connector is shown in
Figure 5-4
.
Step 6
Use the screwdriver to tighten the two captive screws on the terminal block to the mating connector. The
terminal screws are shown in
Figure 5-2
. Torque the terminal block screws to 11 lbf-in.
Step 7
Enable DC power by plugging in the DC power supply cord to the power source, or by enabling power
at the designated circuit.
Power Cycling the Router
There are two reset buttons on the router cable panel, which can be used to power cycle the router and
to reset the router system software to the default configuration. Use the reset buttons as described in this
section.
Caution
When you use the CONFIG Reset button to restore the router to the factory default software
configuration, the current software configuration is permanently deleted from the router.
Accessing the Buttons
You must provide a pin, paper clip, or other thin metal tool to access and press these buttons.
302220