28-4
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 28 Alarms and Statistics
APS Alarms
Clear
APS OK
APS line is up with no alarms.
Clear
APS Deactivated
APS line is down.
Minor
APS Lines looped
APS line is looped.
Minor
APS Remote Signal
Failure
A remote signal failure indicates that there is a problem with the
far end signalling information in the K1K2 bytes.
Minor
APS Channel Mismatch
Can only happen in bidirectional mode and indicates that there
is a problem with the underlying APS channel protocol. The
receive K2 channel number does not equal the transmit K1
channel number.
Minor
APS Protection Switch
Byte Failure
Protection Switch Byte failure or PSB. In bidirectional mode
indicates that there is an invalid K1 byte. The receive K1 request
does not match the reverse request and is less than the transmit
K1 request. In all modes a PSB alarm indicates that K1/K2
protocol is not stable.
Minor
APS Far End Protection
Failure
Far end protection failure indicates that the far end’s protection
line is failing. When there is Signal Failure on the protection
channel, the remote end sees Far End Protection Fail.
Minor
APS Architecture
Mismatch
Architecture mismatch means that the APS configuration on one
end of the line does not match the APS configuration at the other
side of the line. Specifically GR-253 at one end and ITUT at the
other or 1+1 at one end and 1:1 at the other.
Info
APS Init/Clear/Revert
A BXM APS event indicating that the BXM APS has been
initialize or a clear switch has occurred or a revert switch has
occurred.
Info
Cannot perform a
Clear/Revert switch
A BXM APS event indicating that the BXM APS was unable to
perform a clear or revertive switch.
Info
APS Manual switch
A BXM APS event indicating that the BXM APS
has performed a user requested manual switch.
Info
Cannot perform a
Manual switch
A BXM APS event indicating that the BXM APS
was unable to perform a user requested manual switch.
Info
APS Signal Degrade
LoPri switch
A BXM APS event indicating that the BXM APS
performed a switch due to a low priority signal degrade
condition. An automatically initiated switch due to a “soft
failure” condition resulting from the line BER exceeding a
pre-selected threshold (cnfapsln).
Info
Cannot perform a Signal
Degrade LoPri switch
A BXM APS event indicating that the BXM APS
was unable to perform a switch due to a low priority signal
degrade condition.
Info
APS Signal Degrade
HiPri switch
A BXM APS event indicating that the BXM APS performed a
switch due to a high priority signal degrade condition. An
automatically initiated switch due to a “soft failure” condition
resulting from the line BER exceeding a pre-selected threshold
(cnfapsln).
Table 28-2 APS Alarms (continued)
Class
Name
Description
Содержание BPX 8600 Series
Страница 43: ...P A R T 1 The BPX Switch ...
Страница 44: ......
Страница 151: ...P A R T 2 Installation ...
Страница 152: ......
Страница 261: ...P A R T 3 Initial Configuration and Network Management ...
Страница 262: ......
Страница 291: ...P A R T 4 Configuring Connections ...
Страница 292: ......
Страница 481: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 482: ......
Страница 531: ...P A R T 6 BPX Specifications ...
Страница 532: ......
Страница 563: ...P A R T 7 Appendices ...
Страница 564: ......
Страница 624: ...Glossary 24 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...
Страница 630: ...Index 6 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...