A-3
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Appendix A Upgrade Information
Upgrade Options
Table A-2
Upgrade Options
Option
Used when...
Steps
Yred BXMs,
manual
Legacy BXMs are yred
and the “auto BXM
upgrade parameter” is
set to “N” for the
cnfnodeparm
command.
1.
Remove the standby BXM card and replace it with the BXM-E card.
2.
BXM-E card can be flagged as ‘Mismatch’ if the configured channel
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command cnfcdparm <BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
3.
Yred the switch so that the standby BXM-E becomes active.
4.
Repeat steps 1-2 for the other slot. User still can fall back to the legacy
card up to this point.
5.
Upgrade the logical card using the command upgdlogcd <log_card_num>.
Switch software upgrades the logical database from the number of
connections configured on the legacy BXM card to the number of
connections configured in step 2 and 4. From this point on, mismatch is
declared if the legacy card is reinserted.
Note
During upgrading yred BXM cards to BXM-E cards, the
level of service disruption is expected to be the same as the
one experienced when switchyred is executed for yred
legacy BXMs.
Yred BXMs,
automatic
Legacy BXMs are yred
and the “auto BXM
upgrade” parameter is
set to Y for the
cnfnodeparm
command.
1.
Remove the standby BXM card and replace it with the BXM-E card.
2.
BXM-E card can be flagged as ‘Mismatch’ if the configured channel
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command cnfcdparm <BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
3.
Yred switch so that the standby BXM-E becomes active.
4.
Repeat steps 1-2 for the other slot.
5.
Switch software automatically upgrades the logical database when step 4 is
done.
Note
During upgrading yred BXM cards to BXM-E cards, the
level of service disruption is expected to be the same as the
one experienced when switchyred is executed for yred
legacy BXMs.
Содержание BPX 8600 Series
Страница 43: ...P A R T 1 The BPX Switch ...
Страница 44: ......
Страница 151: ...P A R T 2 Installation ...
Страница 152: ......
Страница 261: ...P A R T 3 Initial Configuration and Network Management ...
Страница 262: ......
Страница 291: ...P A R T 4 Configuring Connections ...
Страница 292: ......
Страница 481: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 482: ......
Страница 531: ...P A R T 6 BPX Specifications ...
Страница 532: ......
Страница 563: ...P A R T 7 Appendices ...
Страница 564: ......
Страница 624: ...Glossary 24 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...
Страница 630: ...Index 6 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...