23-3
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 23 Configuring BXM Virtual Switch Interfaces
VSI Configuration Procedures
VSI Configuration Procedures
In the VSI control model, a controller sees the switch as a collection of slaves with their interfaces. The
controller can establish connections between any two interfaces. The controller uses resources allocated
to its partition.
You can assign each VSI interface a default class of service template when you activate it. You can use
the switch software CLI or Cisco WAN Manager to configure a different template to an interface.
The procedure for adding a VSI-based controller such as the MPLS controller to the BPX is similar to
adding an MGX 8220 interface shelf to the BPX. To attach a controller to a node to control the node,
use the
addshelf
command.
The VSI controllers are allocated a partition of the switch resources. VSI controllers manage their
partition through the VSI protocol. The controllers run the VSI master. The VSI master entity interacts
with the VSI slave running on the BXMs through the VSI interface to set up VSI connections using the
resources in the partition assigned to the controller.
To configure VSI resources on a given interface, use the
cnfrsrc
command.
This section provides the basic procedures to:
•
Add a controller
•
View controllers and interfaces
•
Delete a controller
•
Enable VSI ILMI functionality
•
Configure partition resources on VSI
Adding a Controller
To add an MPLS controller to any BXM trunk, use the addshelf command with the V(si) option.
To add an SES PNNI controller, use the addshelf command with an X option.
To identify VSI controllers and distinguish them from feeders, use the vsi option of the
addshelf
command.
To add a SES PNNI controller to a BPX node through an AAL5 interface shelf or feeder type configured
with VSI controller capabilities, use the
addctrlr
command. See “Adding a Controller” later in this
chapter.
If you are adding two controllers that are intended to be used in a redundant configuration, you must
specify the same partition when you add them to the node by using the
addshelf
command.
To add an MPLS controller (or a generic VSI controller that does not need AnnexG protocol):
Step 1
Up the trunk by using the
uptrk
command.
Step 2
Add an MPLS controller by using the
addshelf
command with feeder type set to "V".
Step 3
Display the controllers and interface shelves attached to the node by using the
dspnode
command.
Step 4
Display the VSI controllers on a BPX node by using the
dspctrlrs
command.
Содержание BPX 8600 Series
Страница 43: ...P A R T 1 The BPX Switch ...
Страница 44: ......
Страница 151: ...P A R T 2 Installation ...
Страница 152: ......
Страница 261: ...P A R T 3 Initial Configuration and Network Management ...
Страница 262: ......
Страница 291: ...P A R T 4 Configuring Connections ...
Страница 292: ......
Страница 481: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 482: ......
Страница 531: ...P A R T 6 BPX Specifications ...
Страница 532: ......
Страница 563: ...P A R T 7 Appendices ...
Страница 564: ......
Страница 624: ...Glossary 24 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...
Страница 630: ...Index 6 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...