13-13
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 13 Installing the BPX Switch Cards
Installation of APS Redundant Frame Assembly and Backcards
Figure 13-9 APS 1:1 Redundancy
APS 1+1 Redundancy Installation
APS 1+1 redundancy provides both card and line redundancy. It uses the standard BXM OC-3 and
OC-12 front cards but requires a special APS Redundant Backplane and APS Redundant backcards.
With previous card cages, because of the positioning of mechanical dividers, the APS card pairs could
be inserted only in slots 2 through 5 and 10 through 13. The mechanical dividers are located at slots 1
and 2, 5 and 6, 9 and 10, and 13 and 14.
With current card cages, this limitation is removed so that the APS card pairs can be located anywhere
except BCC cards slots 7 and 8, and ASM card slot 15. An APS 1+1 redundant card pair must be in
adjacent slots (2,3 or 4,5 and so on).
Figure 13-10 APS 1+1 Redundancy
Working line
Protection line
17711
BPX switch
BPX switch
Working line
Protection line
17722
BPX switch
BPX switch
Содержание BPX 8600 Series
Страница 43: ...P A R T 1 The BPX Switch ...
Страница 44: ......
Страница 151: ...P A R T 2 Installation ...
Страница 152: ......
Страница 261: ...P A R T 3 Initial Configuration and Network Management ...
Страница 262: ......
Страница 291: ...P A R T 4 Configuring Connections ...
Страница 292: ......
Страница 481: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 482: ......
Страница 531: ...P A R T 6 BPX Specifications ...
Страница 532: ......
Страница 563: ...P A R T 7 Appendices ...
Страница 564: ......
Страница 624: ...Glossary 24 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...
Страница 630: ...Index 6 Cisco BPX 8600 Series Installation and Configuration Release 9 3 0 Part Number 78 10674 01 Rev D0 July 2001 ...