C i s c o C o n f i d e n t i a l - B e t a R e v i e w R 3 . 7. 1
Hardware Redundancy and Node Administration Commands on Cisco IOS XR Software
show environment
SMR-277
Cisco ASR 14000 Series Router System Management Command Reference
OL-17231-01
Task ID
Examples
The following is sample output from the
show environment
command with the
temperatures
keyword:
RP/0/RP0/CPU0:router#
show environment temperatures
R/S/I Modules Inlet Exhaust Hotspot
Temperature Temperature Temperature
(deg C) (deg C) (deg C)
0/2/* host 31, 27 43, 45 48
cpu 31
fabricq0 46
fabricq1 44
ingressq 34
egressq 41 43
ingresspse 35
egresspse 42
plimasic 30, 31 42
0/RP1/* host 38 44
cpu 36
ingressq 42
fabricq0 43
0/SM0/* host 29, 29 41, 33
describes the significant fields shown in the display.
The following is sample output from the
show environment
command the with the
leds
keyword:
RP/0/RP0/CPU0:router#
show environment leds
0/2/*: Module (host) LED status says: OK
0/2/*: Module (plimasic) LED status says: OK
0/SM0/*: Module (host) LED status says: OK
Task ID
Operations
system
read
Table 28
show environment temperatures Field Descriptions
Field
Description
R/S/I
Rack number, slot number, and interface for which information is
displayed, in the format
rack_num
/
slot_num
/*.
Modules
Module for which temperature information is displayed.
Inlet Temperature (deg C)
Current temperature of the inlet sensor in degrees Celsius.
Note
The inlet temperature corresponds to the room air
temperature entering the router.
Exhaust Temperature (deg C)
Current temperature of the exhaust sensor in degrees Celsius.
Note
The exhaust temperature corresponds to the air being
exhausted from the router.
Hotspot Temperature (deg C)
Displays the current temperature of the hotspot in degrees Celsius.