Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.48 STA-LOCL-RST
Command
STA-LOCL-RST
Instructs the ONS 15216 EDFA2 to restore all the manufacturing default settings. The files on the flash
file system (FFS), the date and time, the sid/tid name (name), and the values of manufacturing calibration
are not affected. This command must be followed by the INIT-SYS command to take effect.
Warning
This command resets the IP address, deletes the user directory, reverts CISCO15 to the default
password, and resets other parameters to restore the unit to its state as shipped from manufacturing.
Syntax
STA-LOCL-RST:[<tid>]::<ctag>;
Example 9-51 STA-LOCL-RST Command
Amp01:ONS15216 EDFA2> STA-LOCL-RST:Amp01::10;
threshholdtype
and
thresholdvalue
pairs
string
Type of threshold that is to be set. The threshold is set to the
thresholdvalue that follows the comma. Possible to specify
values for one or more of the following:
MAXCTMP
Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 65
in units of
°
C.
MAXCTMPHYST
Maximum case temperature hysteresis
(cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°
C.
MINCTMP
Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between –10 and 10, with default of
–5, in units of
°
C.
MINCTMPHYST
Minimum case temperature hysteresis
(cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°
C.
Table 9-54 SET-TH-EQPT Syntax Description (continued)
Parameter
Syntax
Description