F I N A L D R A F T - C I S C O C O N F I D E N T I A L
8-10
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 8 Provisioning Using TL1
Set Password
8.9 Set Password
To restrict access to the ONS 15216 EDFA2, use the ED-PID command (see
“ED-PID” section on
page 9-20
) to change the default user password according to the following syntax:
ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>;
Note that the password must be a string of up to 10 characters, where at least 2 are non-alphabetic
characters and at least 1 is a special character. See
Example 8-9
.
Example 8-9
Changing Current User’s Password Using TL1
sidtidname
:ONS15216 EDFA2>
ED-PID::CISCO15:130::OLDPW,NEWPW;
Note
The default user name for the administrator level is CISCO15 with no default password.
MINCTMPHYST
Minimum
case
temperature
hysteresis
Integer
(0 to 10)
Read-write
Used to set the amount that the case
temperature of the module must rise
above the minimum case temperature
alarm level before the alarm is cleared.
Set the hysteresis at a value that is
appropriate for the application so that
the alarm condition clears when the
input is stable. Consult with the Cisco
TAC to determine the correct value for
your application. As a guideline, Cisco
recommends that the hysteresis value
be set at 1
°
C. Valid entries are between
0 and 10
°
C. Setting this value to 0
disables this option.
Table 8-1
Alarm Threshold Attribute Definitions (continued)
Attribute
Variable
Definition
Syntax
Maximum
Access
Description