F I N A L D R A F T - C I S C O C O N F I D E N T I A L
9-11
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.3 APPLY
Command
APPLY
Applies a software cutover in the memory. There are two boot file entries. This command exchanges boot
file entries 1 and 2 so that when the system is restarted (by the INIT-SYS command), it boots with the
image that was (before the execution of this command) at the second entry.
GAINCHGD
“Overall Gain Changed”
(cerent15216EdfaConstGainOverallGain).
LOSHYSTCHGD
“LOS (loss of signal) Hysteresis Changed”
(cerent15216EdfaLOSHysteresis).
LOSTHCHGD
“LOS (loss of signal) Threshold Changed”
(cerent15216EdfaLOSThreshold).
LPOUTCHGD
“Loss of Output Power Setpoint Changed”
(cerent15216EdfaLpoutSetpoint).
LPOUTDEVCHGD
“Lpout (loss of output power) Deviation Changed”
(cerent15216EdfaLpoutDeviation).
LPOUTHYSTCHGD
“Lpout (loss of output power) Hysteresis Changed”
(cerent15216EdfaLpoutHysteresis).
PREATTCHGD
“Pre-attenuation Changed”
(cerent15216EdfaVariableGainPreAttenuation).
PWRBUSMAXCHGD
“Power Bus Max (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMax).
PWRBUSMINCHGD
“Power Bus Min (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMin).
PWRBUSMODE
“Power Bus Mode Changed”
(cerent15216EdfaPowerBusMode).
MAXCTMPCHGD
“Max Case Temperature Changed”
(cerent15216EdfaCtmpMax).
MAXCTMPHYSTCHGD
“Max Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMaxHysteresis).
MINCTMPCHGD
“Min Case Temperature Changed”
(cerent15216EdfaCtmpMin).
MINCTMPHYSTCHGD
“Min Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMinHysteresis).
CUTOVERRESET
(Software) “Reset after Cutover”
(cerent15216EdfaOpCutover).
SOFTWARELOAD
(New) “Software Load” (cerent15216EdfaOpLoad).
SOFTWARERESET
“Software Reset” (cerent15216EdfaOpReset).
ALL
All condtype preceding.
Table 9-10
ALW-MSG-ALL Syntax Description (continued)
Parameter
Syntax
Description