F I N A L D R A F T - C I S C O C O N F I D E N T I A L
3-15
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 3 Installation
Communications
3.5.5.1 LAN Connection Procedure
Use the following procedure to configure the module to accept SNMP, CLI, and TL1 commands via its
RJ-45 LAN port:
Step 1
The ONS 15216 EDFA2 IP address is factory set at 0.0.0.0. The IP address must be set before the
ONS 15216 EDFA2 can be accessed via the Ethernet port. See
“Set IP Address” section on page 4-3
.
Step 2
Connect ONS 15216 EDFA2 to the network via the module LAN port.
Use a straight-through Cat5 Ethernet cable with RJ-45 connectors to connect to a LAN, or use a
cross-over cable if connecting directly to a PC.
Step 3
At a terminal or workstation, open the Telnet application.
Note
To send CLI and TL1 commands over IP, a Telnet client is required. For SNMP management over
IP, a generic SNMP manager is required.
Step 4
Connect to the ONS 15216 EDFA2 using the module’s IP address.
If you do not specify a port number, the ONS 15216 EDFA2 responds in the shell that the
ONS 15216 EDFA2 is set to (TL1 is the default shell). Specify port number 8023 to access through the
ASH shell or port number 3083 to access through the TL1 shell.
The ONS 15216 EDFA2 login screen appears. See
“Log In via RS-232 (EIA/TIA-232) Port Using
HyperTerminal” section on page 4-1
for the login procedure in ASH shell and
“Log In via RS-232
(EIA/TIA-232) Port Using HyperTerminal” section on page 8-1
for the login procedure in TL1 shell.