Positioning User Manual
35
(Example)
a)
Change the current coordinates
When the M101 Bit is turned ON, the current coordinates will be set as 1000 and the OPR is
completed.
b)
Change the operation speed
When the M101 Bit is turned ON while the speed control is at 500 PPS using FSC or RSC
commands, the current speed is changed to 1,000 PPS.
*Error Code occurs when executing a command to change operation speed during the JOG operation
MOV 1 (Change current coordinates)
MOV 2 (Change operation speed)
MOV 3 (Inching operation)
MOV 6 (Change target address)
Position
Data No.
Control
Pattern
Interpolation
Acceleration
Time
Deceleration
Time
Control
Code
Dwell
Time
Operation
Speed
Target
Address
1
Single
Step
Non-
Interpolation
No. 1
No. 1
FSC or RSC
0
500
0