Positioning User Manual
36
c)
Inching Operation
The example below describes an inching operation that moves the distance of 300 PPS after
configuring the inching speed as 100 PPS. In the X-Axis parameter setting, the inching speed is
configured as 100 PPS and the amount of movement is configured as 300 PPS.
d)
Change Target Address
When executing the position control to the target address (5,000) configured by ABS, INC and
FEED position data, it changes the target address (8,000) configured in the POSCTRL.
Position
Data No.
Control
Pattern
Interpolation
Acceleration
Time
Deceleration
Time
Control
Code
Dwell
Time
Operation
Speed
Target
Address
1
Single
Step
Non-
Interpolation
No. 1
No. 1
ABS, INC,
FEED
0
500
5000