Positioning User Manual
15
b)
Origin Point (ZERO) Detection after decelerating when DOG signal is ON
OPR begins with OPR High Speed in the OPR Direction configured at OPR parameters until DOG signal is
turned ON to cause OPR to decelerate with OPR Low Speed. After the deceleration, the first ZERO signal
is detected as well as the OPR ends at the same time.