Positioning User Manual
7
1.4
Specifications
1.4.1
Performance Specifications
The following describes the performance specifications of CIMON PLC-S built-in Positioning function.
Item
Specification
Number of Control Axis
2 Axes
Interpolation
2 Axes Linear Interpolation (Less than 5kpps)
Pulse Output Signal
Open Collector Type (DC24V)
Pulse Output Type
Pulse + Direction Output
Control Type
Position control, Speed control, Speed/Position switching,
Position/Speed switching
Control Unit
Pulse
Position Data
30 Position Data Per Axis (Operation step number : 1 .. 30)
How to Configure Position Data
CICON Special Program (Permanent auto preservation)
Positioning Monitor
Dedicated monitoring window provided by CICON
Back-Up
Parameter, operation data → Saved in Flash memory
Positioning Method
Absolute / Incremental
Position Address Range
-2,147,483,648
~
2,147,483,647 (Pulse)
Speed Range
1
~
100,000 pps (1 pps unit)
Acceleration/Deceleration Type
Trapezoid-shaped
Acceleration/Deceleration Time
0
~
100,000 mSec.
(Selectable from 4 types of acceleration/deceleration patterns)
Maximum Output Pulse (X-Axis)
Position Control / Speed Control: 100kpps
Maximum Output Pulse (Y-Axis)
Position Control: 5kpps, Speed Control: 100kpps
Maximum Connection Distance
2m
1.4.2
Input and Output Signal Specifications
Item
Specification
Rated Input Voltage
24V DC (20.4V
~
28.8V)
Rated Input Current
About 7 mA / 24V
Insulation type
Photo-coupler insulated
Input Impedance
About 3.3kΩ
On Voltage (Min.)
20.4V or above
Off Voltage (Max.)
6V or less
Response time
0.5mSec or less (Used for positioning)
Min. Input Width
100 µs or above
Ext. Upper Limit Input X07 (X axis) / X0A (Y axis), B contact
Ext. Lower Limit Input X08 (X axis) / X0B (Y axis), B contact
DOG Input
X0C (X axis) / X0E (Y axis), A contact
Zero Input
X0D (X axis) / X0F (Y axis), A contact