Programmable DC Electronic Load 63600 Series Operation & Programming Manual
4-14
4.4.5 Setting CP Values
When operate in CP mode, the VFD displays CP mode.
0 . 0 0 0 0 mV
0 . 0 0 0 0 mA
0 . 0 0 0 0 mW
There are three power ranges for CP operation: high power range, middle power range, and
low power range. ALL power levels are programmed in watts. The slew rate levels are
programmed in mA/
μs at low range and in A/μs at middle range and high range.
The following examples show how to set the CP values of Load module for model 63630-80-
60.
1.
Select Range
Select proper range, by pressing
key, until the LED of the desired range above
the
key is lights up. High range is used when higher power level is required, and
LOW range is used when better resolution is required.
Select LOW range, by pressing
key, until the LED “L” above the
key
lights up.
The sequence of range selection after pressing
key is as follows:
High range
Middle range
Low range goes back to High range
2.
Select state A/B for single channel module
For single channel module, press the
key to select state A or state B, then the
LED “A” or LED “B” above the key
lights up. Select state A, by pressing the
key to select state A, then the LED “A” above the key
lights up.
3.
Set Power Level
There are 15,000 discrete steps from 0 to full scale in each range. Press the
key to enter into the editing mode. Turn the Rotary knob to change the display value to
2 watts, then press
key to confirm.
2.0000 W
The user may use
or
key to change the cursor position to different digit of
data, then turn the rotary knob to change the value of that digit.
If the user does not use
or
key to display the cursor, then resolution of the
value changes according to the rotary knob turning speed
RANGE
RANGE
RANGE
RANGE
RANGE
A/B
A/B
A/B
A/B
EDIT
ENTER
CP
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......