Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5-50
Setting Example: CURR:DYN:RISE 2.5
Set rising slew rate to 2.5A/
μs.
CURR:DYN:RISE 1A/
μs
Set rising slew rate to 1A/
μs.
CURR:DYN:RISE MAX
Set rising slew rate to the maximum
value of dynamic load.
CURR:DYN:RISE MIN
Set rising slew rate to the minimum
value of dynamic load.
Query Syntax:
CURRent:DYNamic:RISE?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = A/
μs]
Query Example:
CURR:DYN:RISE?
CURR:DYN:RISE? MAX
CURR:DYN:RISE? MIN
CURRent:DYNamic:T1
Type:
Channel-Specific
Description:
Set duration parameter T1 for constant current dynamic mode.
Setting Syntax:
CURRent:DYNamic:T1<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 10
μs ~ 100s, Resolution = 10μs, Unit = Second
Setting Example: CURR:DYN:T1 10ms
Set the dynamic duration T1 = 10ms.
CURR:DYN:T1 2
Set the dynamic duration T1 = 2s.
CURR:DYN:T1 MAX
Set the dynamic duration T1 as
maximum value.
CURR:DYN:T1 MIN
Set the dynamic duration T1 as
minimum value.
Query Syntax:
CURRent:DYNamic:T1?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example:
CURR:DYN:T1?
CURR:DYN:T1? MAX
CURR:DYN:T1? MIN
CURRent:DYNamic:T2
Type:
Channel-Specific
Description:
Set duration parameter T2 for constant current dynamic mode.
Setting Syntax:
CURRent:DYNamic:T2<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 10
μs ~ 100s, Resolution = 10μs, Unit = Second
Setting Example: CURR:DYN:T2 10ms
Set the dynamic duration T2 = 10ms.
CURR:DYN:T2 2
Set the dynamic duration T2 = 2s.
CURR:DYN:T2 MAX
Set the dynamic duration T2 as
maximum value.
CURR:DYN:T2 MIN
Set the dynamic duration T2 as
minimum value.
Query Syntax:
CURRent:DYNamic:T2?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example:
CURR:DYN:T2?
CURR:DYN:T2? MAX
CURR:DYN:T2? MIN
CURRent:STATic:FALL
Type:
Channel-Specific
Description:
Set the falling slew rate of current for constant current static mode.
Setting Syntax:
CURRent:STATic:FALL<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CURR:STAT:FALL 2.5
Set falling slew rate to 2.5A/
μs.
CURR:STAT:FALL 1A/
μs
Set falling slew rate to 1A/
μs.
CURR:STAT:FALL MAX
Set falling slew rate to the
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......