Programmable DC Electronic Load 63600 Series Operation & Programming Manual
7-12
Figure 7-1
Figure 7-2
7.3.5 Dynamic & Slew Rate Circuit Test
This test verifies the slew rate circuit operation and the dynamic current waveform period
specifications when the module dynamic is operating in CC mode.
Connect the Load module, DC source, oscilloscope, and current shunt as Figure 7-3 shows.
Use oscilloscope to measure the waveform that passes through the shunt resistor
measurement port. To reduce the current waveform overshoot caused by cable inductance,
make the cables as short as possible. Adjust the oscilloscope for rise or fall time display. The
rise time measured from 10% to 90% and the fall time from 90% to 10%.
Press
on the front panel of Electronic Load to show
DYNA
as the figure appeared
below.
DYNA
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......