Programmable DC Electronic Load 63600 Series Operation & Programming Manual
4-40
ENTRY MODE. The HIGH/LOW percentage range is from 0 to 100%. And also may choose
OFF to close Voltage specification judgment. The default setting of HIGH and LOW is 100%.
The CENTER value is half of the range.
V_CENT
: ------V
V_HIGH
: ------%
V_LOW : ------%
Set Current specification
. There are three levels for Current specification: CENTER, HIGH
and LOW. The CENTER level must be set by the value of channel input reference level. The
HIGH and LOW levels can be set by the value or percentage selected in configuration SPEC
MODE. The HIGH/LOW percentage range is from 0 to 100%. And also may choose OFF to
close Current specification judgment. The default of CENT, HIGH and LOW is dot line which
means there is no specification judgment.
I_CENT
: ------A
I_HIGH
: ------%
I_LOW
: ------%
Set Power specification
. There are three levels for Power specification: CENTER, HIGH
and LOW. The CENTER level must be set by the value of channel input reference level. The
HIGH and LOW levels can be set by the value or percentage selected in configuration SPEC
MODE. The HIGH/LOW percentage range is from 0 to 100%. And also may choose OFF to
close Power specification judgment. The default of CENT, HIGH and LOW is dot line which
means there is no specification judgment.
P_CENT
: ------W
P_HIGH
: ------%
P_LOW : ------%
Then the display will go to the first editing page again.
To leave out of the GO/NG SPEC page of system configuration, you need to press
and
simultaneously to go back to the page of system configuration.
4.7.3 Setup of REMOTE
The remote operation of Load can be done through GPIB, USB or Ethernet. These
connectors on the rear panel connect the Load to the controller or computer. The GPIB and
Ethernet interface of the Electronic Load is optional.
Press
and
at the same time to enter into the system configuration page and
turn the Rotary knob to change the display value to 3, then press
key into REMOTE
edit page of system configuration.
ENTER
ENTER
ENTER
ADVA
ADVA
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......