Remote Operation
5-31
ADV:OCP:SPEC:L 500mA
Set low level current = 0.5A.
ADV:OCP:SPEC:L MAX Set low level current = maximum
value.
ADV:OCP:SPEC:L MIN
Set low level current = minimum value.
Query Syntax:
ADVance:OCP:SPECification:L?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Ampere]
Query Example:
ADV:OCP:SPEC:L?
ADV:OCP:SPEC:L? MAX
ADV:OCP:SPEC:L? MIN
ADVance:OCP:STEP
Type:
Channel-Specific
Description:
Set step count for OCP test mode.
Setting Syntax:
ADVance:OCP:STEP<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 1000, Resolution = 1, Unit = None
Setting Example:
ADV:OCP:STEP 500
Set step count = 500.
ADV:OCP:STEP MAX
Set step count = maximum value.
ADV:OCP:STEP MIN
Set step count = minimum value.
Query Syntax:
ADVance:OCP:STEP?[<space><MAX | MIN>]
Return Parameters:<NR1>, [Unit = None]
Query Example:
ADV:OCP:STEP?
ADV:OCP:STEP? MAX
ADV:OCP:STEP? MIN
ADVance:OCP:TRIGger:VOLTage
Type:
Channel-Specific
Description:
Set trigger voltage for OCP test mode.
Setting Syntax:
ADVance:OCP:TRIGger:VOLTage<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example:
ADV:OCP:TRIG:VOLT 0.5
Set trigger voltage = 0.5V.
ADV:OCP:TRIG:VOLT 500mV
Set trigger voltage = 0.5V.
ADV:OCP:TRIG:VOLT MAX
Set trigger voltage = maximum
value.
ADV:OCP:TRIG:VOLT MIN
Set trigger voltage = minimum
value.
Query Syntax:
ADVance:OCP:TRIGger:VOLTage?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example:
ADV:OCP:TRIG:VOLT?
ADV:OCP:TRIG:VOLT? MAX
ADV:OCP:TRIG:VOLT? MIN
ADVance:OCP:LACTh
Type:
Channel-Specific
Description:
Set load latch function for OCP test mode.
Setting Syntax:
ADVance:OCP:LATCh<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example:
ADV:OCP:LATC OFF
Set latch = OFF
ADV:OCP:LATC 1
Set latch = ON
Query Syntax:
ADVance:OCP:LATCh?
Return Parameters:<CRD>, OFF, ON [Unit = None]
Query Example: ADV:OCP:LATC?
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......