Remote Operation
5-53
Type:
Channel-Specific
Description:
Set the end of frequency for constant current frequency sweep
mode.
Setting Syntax:
CURRent:SWEep:FEND<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example:
CURR:SWE:FEND 1000
Set frequency = 1kHz
CURR:SWE:FEND 1kHz
Set frequency = 1kHz
CURR:SWE:FEND MAX
Set frequency = maximum value.
CURR:SWE:FEND MIN
Set frequency = minimum value.
Query Syntax:
CURRent:SWEep:FEND?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example:
CURR:SWE:FEND?
CURR:SWE:FEND? MAX
CURR:SWE:FEND? MIN
CURRent:SWEep:FSTArt
Type:
Channel-Specific
Description:
Set the start of frequency for constant current frequency sweep
mode.
Setting Syntax:
CURRent:SWEep:FSTArt<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example:
CURR:SWE:FSTA 1000
Set frequency = 1kHz
CURR:SWE:FSTA 1kHz
Set frequency = 1kHz
CURR:SWE:FSTA MAX
Set frequency = maximum value.
CURR:SWE:FSTA MIN
Set frequency = minimum value.
Query Syntax:
CURRent:SWEep:FSTA?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example:
CURR:SWE:FSTA?
CURR:SWE:FSTA? MAX
CURR:SWE:FSTA? MIN
CURRent:SWEep:FSTEp
Type:
Channel-Specific
Description:
Set the step of frequency for constant current frequency sweep
mode.
Setting Syntax:
CURRent:SWEep:FSTEp<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.01Hz ~ 50kHz, Resolution = 0.01Hz, Unit = Hertz
Setting Example:
CURR:SWE:FSTE 1000
Set frequency = 1kHz
CURR:SWE:FSTE 1kHz
Set frequency = 1kHz
CURR:SWE:FSTE MAX
Set frequency = maximum value.
CURR:SWE:FSTE MIN
Set frequency = minimum value.
Query Syntax:
CURRent:SWEep:FSTE?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Hertz]
Query Example:
CURR:SWE:FSTE?
CURR:SWE:FSTE? MAX
CURR:SWE:FSTE? MIN
CURRent:SWEep:IMAXimum
Type:
Channel-Specific
Description:
Set the maximum current for constant current frequency sweep
mode.
Setting Syntax:
CURRent:SWEep:IMAXimum<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CURR:SWE:IMAX 20
Set max current = 20A.
Содержание 63600 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual Version 2 2 July 2017...
Страница 8: ...vi...
Страница 9: ...vii...
Страница 10: ...viii...
Страница 16: ......
Страница 39: ...General Information 1 19 Module outline Unit mm 142 85 62 510 36 6 32 UNIT mm 63610 80 60 63610 80 80...
Страница 40: ......
Страница 110: ...Programmable DC Electronic Load 63600 Series Operation Programming Manual 4 34...
Страница 132: ......
Страница 252: ......