82
DWU951 (DD1-WU80P/81P) / DWX951 (DD1-WX80P/81P) / DXG1051 (DD1-X100P/101P)
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
Page 82 / 118
Disassembling
1) Disconnect all the cables on the AC WATCH PCB.
2) Remove 2 screws to detach the AC WATCH PCB.
3) Separate the AC shield and the AC holder.
䖃
AC WATCH PCB
CNAWD
T3x12 black screws
ATTENTION
Clip AC WATCH PCB
under the hooks on the
holder.
Torque: 0.68-0.88Nm
CNAWD
Pass CNAWD through this hook.
Assembling
1) Attach the AC shield on the AC holder.
2) Put the AC WATCH PCB in place on the holder and screw down.
3) Connect CNAWD and wire it as below.
AC WATCH
PCB
T3x12 black screws
AC holder
AC shield