42
DWU951 (DD1-WU80P/81P) / DWX951 (DD1-WX80P/81P) / DXG1051 (DD1-X100P/101P)
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
Page 42 / 118
"
' In a normal state
' Warnings and Errors
The Status Monitor displays the state of the projector in three lines.
The Status Monitor displays a warning or an error with larger letters when it is detected. Refer to
the table on the next page for the correspondence among the displays of the Status Monitor and
indicator lamps and how to cope with it.
NOTE:
on the 2nd line of the monitor.
temperature is measured inside the projector.
NOTE:
#
1st line
: Displays the condition of the projector. While the lamp is on, the selected port is displayed.
Displayed conditions are as below;
STANDBY: The projector is in standby mode.
WARM UP: The projector is warming up.
SEARCHING: The projector is searching an input signal.
COOL DOWN: The projector is cooling down.
2nd line
: Displays the condition of the detected input signal while the lamp is on. Otherwise, displays the
serial number of the projector.
Displayed conditions are as below;
SYNC OUT^
NO SIGNAL: There is no input signal.
CONNECTED^ #
transferred to the projector while the LAN is selected.
HOLD: # #>"
NOT CONNECTED: # #>"
3rd line
: Displays supplied voltage and peripheral temperature in Celsius while the lamp is on.
Warnings;
AIR (AIR FLOW): The internal temperature is rising.
COLD: The inside of the projector is cooled excessively.
FILTR^\
SHUTR: The mechanical shutter does not open.
SHIFT^ #
LAMP1: Lamp 1 does not light.
LAMP2: Lamp 2 does not light.
HUMID: Humidity is too high.
C.WHL: One of the color wheels is out of order.
Errors;
?}^ +
FAN: The cooling fan is not operating.
LAMP: Neither lamp lights.
TEMP: The inside of the projector is overheating.
OTHER: Miscellaneous error in the ENGINE assembly is detected.
'Error (and warning) log
* # #
% '
*
usage time in the Lamp log and the Filter log when each error occurred.
NOTE:
If no error or less than 10 errors have occurred, "NO DATA" is displayed in spite of occurred error in the error log.
Refer to the table on the next page for the correspondence among the displays of the Status Monitor and indicator lamps.