Page 64 Copyright CPS America Co., Ltd.
Model
CPS
SCE4KTL-O/US
CPS
SCE5KTL-O/US
CPS
SCE6KTL-O/US
CPS
SCE7KTL-O/US
277V
system
5
248~300V
Rated Output Frequency
60Hz
Power Factor
>0.99
Output Frequency Range
6
59.3-60.5Hz
Current THD
<3%
AC Disconnection Type
Switch
Nominal AC current @ 208Vac
18.3A
22.1A
28.9A
33.7A
Nominal AC current @ 240Vac
16.7 A
20.8 A
25 A
29.2A
Nominal AC current @ 277Vac
14.4 A
18.1 A
21.7 A
25.3A
Max. AC current
7
@ 208Vac
system
18.5A
22.5A
30A
35A
Max. AC current
7
@ 240Vac
system
18.5A
22.5A
28.5A
33.2A
Max. AC current
7
@ 277Vac
system
16.4A
20.5A
24.6A
28.7A
System
Topology
Transformerless
Max. Efficiency
97.5%
CEC efficiency
97%
Stand-by / Night Consumption
8
<7W / <0.2W
Environment
Protection Degree
NEMA 3R
Cooling
Forced air cooling
Operating Humidity
0-95%, non-condensing
Operating Altitude
6562ft / 2000m without derating
Operating temperature range
9
-25 ~ +50
℃
5
Regulation range: 244~305Vac
6
Regulation range: 59.3~60.5 Hz
7
The max OCPD( Over Current Protection Device) rating should not exceed the value in Table 6.3.1
8
Test condition of night power consumption: 240Vac
9
The LCD panel working temperature must be above -20
℃
. The inverter can work normally without LCD display between -20
℃
and -25
℃
.