Copyright CPS America Co., Ltd. Page 63
10. Specifications
Model
CPS
SCE4KTL-O/US
CPS
SCE5KTL-O/US
CPS
SCE6KTL-O/US
CPS
SCE7KTL-O/US
Market
North America
Input (DC)
Max. PV Power
4.8 KW
6 KW
7.2 KW
8.4 KW
Nominal DC Input Power
4.1KW
5.2KW
6.2KW
7.3KW
Nominal DC voltage
360 V
360 V
360 V
360 V
Max. PV open voltage
600 V
600 V
600 V
600 V
Start-up DC Input Voltage
150 V
150 V
150 V
150 V
Operating DC Input Voltage
Range
1
100 ~ 515 V
100 ~ 515 V
100 ~ 515 V
100 ~ 515 V
MPPT Voltage Range
225 ~ 500 V
200 ~ 500 V
200 ~ 500 V
200 ~ 500 V
Number of MPP tracker(s)
1
1
1
1
Number of DC Input Pairs
4
4
4
4
Max. DC current
19 A
26 A
32 A
37 A
Max. Input Current per String
20A
20A
20A
20A
DC insulation resistance
2
> 2M
Ω
DC Disconnection Type
Switch
Output (AC)
Nominal AC power @ 240Vac &
277Vac
4000W
5000W
6000W
7000W
Nominal AC power @ 208Vac
3800W
4600W
6000W
7000W
Max. AC power @ 240Vac &
277Vac
4000W
5000W
6000W
7000W
Max. AC power @ 208Vac
3800W
4600W
6000W
7000W
Grid Connection Type
Single phase / 240V Split phase (Refer to 5.4)
Rated Output Voltage
240V Split phase
Operational voltage
range
/ Firmware setting
value
208V
system
3
186~225V
240V
system
4
215~260V
1
This is the DC voltage range that inverter can feed power to the grid.
2
The DC resistance requirement for positive or negative terminal to chassis ground.
3
Regulation range: 183~229Vac
4
Regulation range: 211~264Vac