REFERENCE
EDMS NO.
REV.
VALIDITY
TOF-TAR-PRD-0001
1867100
1.0
RELEASED
Page 55 of 93
Name of task
380. Remove bracket
top plates
Exposed people
1
Local dose rate
100 µSv/hr
Workforce
3 people (1 down, 1 or 2 in
Tech Gallery)
Time needed
10 min
Calculated dose
Responsible
EN-STI
Involved
EN-EA/ EN-HE/ HSE-RP/ EN-CV
Comments:
Pipes should be closed with plastic bags.
The plates will be stored in the ISR8 Storage Area.
A manual winch will be needed to recover persons
in the case of an emergency. The intervention
inside the pit will be confined space work, so all the
necessary safety measures should be taken.