REFERENCE
EDMS NO.
REV.
VALIDITY
TOF-TAR-PRD-0001
1867100
1.0
RELEASED
Page 52 of 93
Name of task
355. Install the solid
version of shielding
block 1
Exposed people
Local dose rate
70 µSv/hr
Workforce
3 people
Time needed
1 hour
Calculated dose
Responsible
EN-EA
Involved
EN-EA/EN-STI/ EN-CV/ HSE-RP
Comments:
This task will be performed from the Technical
Gallery.
A solid version of the shielding block 1 exists (with no
hole in the middle). The original shielding block 1 will
be exchanged by the solid one, in order to:
-
Provide a base to work from, for the next tasks.
-
Protect from the radiation from the target.