Technical instructions CONTROLLER -
CPREG-Touch
80
Heating configuration (markings on the display)
13.83 Configuration H-7-1
13.84 Configuration H-8-0
13.84.1 Configuration H-8-0
bar
M
8
2
bar
M
13
14
M
8
2
20
bar
2
8
M
24
25
20
20
17
17
9 5
9 5
9 5
4
3
4
3
4
3
a)
Boiler temp. maintenance switched off (authorized service technician has switched off boiler boiler temp.
maintenance under INSTALLATION), the boiler operates only according to the heating or DHW request.
Tboiler: -> DHW: 80°C (70-80°C) Tdhw: - DHW: Tdhw=Tboiler=80°C
- Mode: - DHW: 70°C (70-80°C) - Mode: - DHW: Tdhw=Tboiler=70°C
dTboiler: - DHW: 10°C (5-15°C) dTdhw: - DHW: 15°C (10-40°C)
- Mode: DHW: 10°C (5-10°C) - Mode: DHW: 15 (10-40°C)
b)
Boiler temperature maintenance is not switched off, the boiler maintains the set boiler temperature.
Tboiler:-> DHW: 80°C (70-90°C) Tdhw:- DHW: Tdhw=Tboiler=80°C
- Mode: - DHW: 10°C (5-10°C) - Mode: - DHW: 15 (10-40°C)
dTboiler: - DHW: 10°C (5-15°C) dTdhw: - DHW: 15°C (10-40°C)
- Mode: DHW: 10°C (5-10°C) - Mode: DHW: 15 (10-40°C)
Temperatures:
a) Circuit 1:
Const. temp. day: 60°C (20-80°C)
Const. temp. night: 60°C (20-80°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
b) Circuit 1:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
Temperatures:
EKO-CKB P + Cm Pelet-set
EKO-CKB P + Cm Pelet-set
*EKO-CKB P + Cm Pelet-set
*DIRECT HEATING CIRCUITS WITH PUMPS
Temperatures:
Tboiler:
- Mode:
dTboiler:
- Mode:
-> DHW: 80°C (70-80°C)
-> DHW: 70°C (70-80°C)
- DHW: 10°C (5-15°C)
- DHW: 10°C (5-10°C)
Tdhw:
- Mode:
dTdhw:
- Mode:
- DHW: Tdhw=Tboiler=80°C
- DHW: Tdhw=Tboiler=70°C
- DHW: 15°C (10-40°C)
- DHW: 15 (10-40°C)
a)
Boiler temperature maintenance switched off (authorized service technician has switched off boiler boiler temperature
maintenance under INSTALLATION), the boiler operates only according to the heating or DHW request.
Note:
in this configuration, switching off the boiler temperature maintenance only makes sense if one or more CM2Ks are installed.
Tboiler: -> DHW: 80°C (70-80°C) Tdhw: - DHW: Tdhw=Tboiler=80°C
- Mode: - DHW: 70°C (70-80°C) - Mode: - DHW: Tdhw=Tboiler=70°C
dTboiler: - DHW: 10°C (5-15°C) dTdhw: - DHW: 15°C (10-40°C)
- Mode: DHW: 10°C (5-10°C) - Mode: DHW: 15 (10-40°C)
b)
Boiler temperature maintenance is not switched off, the boiler maintains the set boiler temperature.
Tboiler:-> DHW: 80°C (70-90°C) Tdhw:- DHW: Tdhw=Tboiler=80°C
- Mode: - DHW: 10°C (5-10°C) - Mode: - DHW: 15 (10-40°C)
dTboiler: - DHW: 10°C (5-15°C) dTdhw: - DHW: 15°C (10-40°C)
- Mode: DHW: 10°C (5-10°C) - Mode: DHW: 15 (10-40°C)