FUEL SENSOR
E119
Possible cause:
Interruption in the cables between the sensor
and controller, connections on the controller, cold junction or
defective sensor.
Boiler status:
Entering the extinguishing phase S7 (S7 – 1).
Troubleshooting:
Call an authorized serviceman who will
check the sensor position, check the damage/accuracy of the
sensor and cable, check the contacts on the connectors.
E117
NOT ACTIVE
E118
NOT ACTIVE
ERROR
FLAP NOT CLOSED
E120
Possible cause:
The vacuum suction flap is blocked with
pellets, dirty or to far away flap sensor.
Boiler status:
The boiler operates normally.
Troubleshooting:
Check if the vacuum suction flap is blocked
with pellets, check if the flap sensor is dirty with dust, check if
the flap sensor has a 1 mm distance from the flap, check if the
flap sensor responds to the flap (the LED light on the sensor
lights).
NO PELLETS
E121
Possible cause:
No pellets in the pellet tank, blocked flexible
tubes, the turbine net is filled with dust, the exit from the bigger
tank is filled with dust.
Boiler status:
The boiler operates normally.
Troubleshooting:
Please check the pellet level in the tank,
check if the flexible tubes are blocked, check if the turbine net
is full with dust, check if the exit from the bigger tank is full with
dust.
E123
NOT ACTIVE
E122
Possible cause:
Interrruption in the el. cables between the
controller and the mole/screw (feeder) in the tank.
Boiler status:
The boiler operates normally.
Troubleshooting:
Call an authorized serviceman who will check
the el. connections on the mole/screw(feeder) in the tank, check
the contacts on the connectors.
MOLE OR SCREW
NOT WORKING
E124
NOT ACTIVE
Errors
Technical instructions CONTROLLER -
CPREG-Touch
102