Operation mode
Technical instructions CONTROLLER -
CPREG-Touch
37
5.6. STANDARD EQUIPMENT
This option is used for view (adjusting) standard equipment of Cm Pelet-set_Touch.
Options:
- sensors -
it is only possible to view the type of sensor (PT1000 – factory or NTC 5K)
- photocell -
it is only possible to preview the photocell settings
- 1st circuit / 2nd circuit -
the user settings of the heating circuits can be adjusted
- DHW
- DHW can be set (on / off) and if recirculation is switch on can be set also "Recirculation operation time" and
"Recirculation pause".
- mixing valve -
(with actuator (backflow protection)) it is possible to check the settings: "Valve time" (opening time of 0-
100%, all configuration with mixing valve), "Min. opening" (after the temperature of the backflow exceeds 60 ° C the
mixing valve opens to a set percentage, if the temperature of the recovery falls again below 60 ° C the mixing valve
closes, this is only possible for the "H" configurations that actively activate the mixing valve).
NOTE:
- some of the options in this menu are DISABLED and could not be changed. It only serves to view the set value. The
display in this menu depends on the selected configuration (XYZ).
5.6.1. SENSORS
This option is used for view the selected sensors type (NTC 5K or PT1000).
Factory: PT1000
Options: Pt1000 / NTC 5K
5.6.2. PHOTOCELL
This option is used to view the selected photocell parameters.
5.6.3/5.6.4. 1. CIRCUIT / 2. CIRCUIT
This option is used for adjusting the mixing heating circuits.
NOTE:
some parameters are shown in"OPERATION" menu but can't be
changed. They can be changed only in "INSTALLATION" menu
which is under PIN (only for authorized serviceman).