Technical instructions CONTROLLER -
CPREG-Touch
52
M
M
bar
1
11
12
10
16
17
13
13
M
bar
1
11
12
10
16
13
17
18
14
19
Heating configuration (markings on the display)
13.7. Configuration A-2-0
EKO-CK P + Cm Pelet-set
Temperatures:
Tboiler: 80°C (80-90°C)
dTboiler: 10°C (5-15°C)
Tbuf: 80°C (70-80°C)
dTbuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (5-50°C)
Tbuf min.: 20°C (5-85°C)
13.8. Configuration A-2-1
EKO-CK P + Cm Pelet-set
Temperatures:
Tboiler: 80°C (80-90°C)
dTboiler: 10°C (5-15°C)
Tbuf: 80°C (70-80°C)
dTbuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°C (10-70°C)
dTdhw: 5°C (5-50°C)
Tbuf min.: 20°C (5-85°C)
1. Circuit:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
13.9. Configuration A-2-2
EKO-CK P + Cm Pelet-set
Temperatures:
Tboiler: 80°C (70-90°C)
dTboiler: 10°C (5-15°C)
Tbuf: 80°C (70-80°C)
dTbuf: 10°C (5-30°C)
dTbuf-off: 5°C (3-50°C)
Tdhw: 50°C (10-60°C)
dTdhw: 5°C (5-50°C)
Tbuf min.: 20°C (5-85°C)
1. Circuit, 2 Circuit:
Const. temp. day: 60°C (20-90°C)
Const. temp. night: 60°C (20-90°C)
Day room temp.: 20°C (5-30°C)
Night room temp.: 20°C (5-30°C)
bar
1
11
12
10
16
17
19
18
18
19
14
15
5
6
5
6
5
6
3
4
3
4
3
4