THE PARAMETERS ADJUSTING
Technical instructions CONTROLLER -
CPREG-Touch
23
The parameters adjusting
There are 4 different menu types for adjusting the parameters:
A - this menu is used to set the parameters that have numerical values (°C, RPM, time...)
example
: adjust the burner fan rpm, adjusting the boiler temp. etc...
B - this menu is used to set parameters that must be selected (marked) to be enabled and there can be multiple selected
(enabled) items
NOTE: some enabled options disable another one (they can't be enabled at the same time)
example
: enable additional equipment: flap, air cleaning, CM2K, Cm-WiFi-box...
C - this menu is used to set the parameters that must be selected but there can be only one selected item
example
: set the type of the DHW sensor
D - this menu is used to set the parameters where are many items to be adjusted
example:
adjust the burner working parameters on power P2
A
B
C
D