CLASSIC EDGE OUTDOOR FURNACE • OWNER'S MANUAL

Maintenance

SERVICE INTERVAL

See Section Number

Before first operation

of season

Daily

W

eekly

Monthly

Semi-AnnuallyPost Season

Other

Inspect primary and secondary combustion air elbows.

OPERATION

Broadcast Ashtrol in firebox.

3-3

3-1

3-5

3-2

Check water level.

Inspect firebox door seal.

Check vent cap.

Remove ash.

Inspect firebox and firebox ash area.

Inspect and clean combustion air outlets.

Clean heat exchangers.

Inspect Reaction Chamber.

Inspect chimney.

Check pH and nitrite levels of water.

3-4

3-9

3-10

3-11

3-13

Grease bypass door handle (Edge 750 models only)

3-14

3-7

3-8

3-6

A

Daily, or as needed.

G

Or as needed.

B

Twice a week.

C

Weekly until interval for your application can be determined.

D

When new, after three months, then every six months thereafter.

F

Frequency will vary depending on heat load requirements, type of wood used and the moisture

content of the wood.

E

Refer to 

Testing Treated Water in the Outdoor Furnace.

A

C

A

C

C

C

D

Inspect and clean the combustion fan and inlet screen.

3-11

Oil the combustion fan.

D

Regular maintenance and inspections can

help extend the life of your outdoor furnace

and prevent high-cost repairs. This table is

meant to serve as a general guideline until

you become acquainted with how the outdoor

furnace operates with your specific application.

3-5

Inspect and lubricate door latch bushings.

G

3-4

Scrape firebox door frame; use cleaning rod in ash.

A

Inspect secondary air charge tube and refractory.

3-12

PREVENTIVE MAINTENANCE SCHEDULE

E

F

Perform a complete firebox cleaning.

3-15

F

F

NOTE: Check daily for build-up of creosote in the lower corners and around the air outlets until

experience shows how often cleaning is necessary.

B

G

Содержание CLASSIC EDGE 350

Страница 1: ...ammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Immediately call your gas sup...

Страница 2: ...and heat exchange efficiency with a single fuel load without refueling Results vary based on wood species wood quality wood quantity and moisture content Efficiencies are determined under the same te...

Страница 3: ...the Coal Bed 14 Ash Removal Frequency 14 Cold Start Firing 14 Adding Heat Load 16 AddingWood Best Practices for Frequency and Amount 17 Why a 12 Hour BurnTime 20 Maintenance 21 Control Locations 22 R...

Страница 4: ...operly use a moisture meter to test firewood before using in a wood burning stove or fireplace Wet wood can create excessive smoke which is wasted fuel Split Stack Cover and Store Video http www youtu...

Страница 5: ...plementary information worthy of particular attention relating to installation operation or maintenance of the outdoor furnace but is not related to a hazardous condition Be sure to follow all instruc...

Страница 6: ...urnace enclosure Foundations may consist of concrete crushed rock or patio blocks Do not use any combustible materials for the foundation CAUTION 2015 Central Boiler Outdoor furnace must be installed...

Страница 7: ...tion purposes only 118 1330 PEX Pipe 296 Swing Check Valve 198 6054 6764 5000018 224 388 388 171 1330 5926 556 3042 5926 3 4 Power disconnect circuit breaker shuts off all power excluding outlet Centr...

Страница 8: ...hten all hardware securely NOTE A hole for the ground terminal has been pre punched in the outdoor furnace base near the pumps Furnace Installation Connecting toYour Existing System A common installat...

Страница 9: ...ller must comply with all applicable codes and regulations NOTE Any electrical installation should be done by a qualified installer in accordance with applicable codes NOTE A certified electrician mus...

Страница 10: ...6 CLASSIC EDGE OUTDOOR FURNACE OWNER S MANUAL...

Страница 11: ...here are dry conditions or where there is combustible material near the unit unless the installation of a spark arrester is prohibited by local requirements Use common sense to avoid potential fires i...

Страница 12: ...sight gauge Corrosion Inhibitor Plus must be added before the initial fill seeWater Quality and Maintenance Disconnect the electrical power to the outdoor furnace before replacing an electrical compon...

Страница 13: ...o open or close This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to gree...

Страница 14: ...Is approximately 60 70 of the length of the firebox Typically weighs 10 15 pounds per cubic foot for heavy heat loads Pieces of wood that are too large can reduce output capacity because they burn sl...

Страница 15: ...e of the outdoor furnace The higher the moisture content of the wood being burned the harder it is to maintain a glowing coal bed because it burns more slowly NOTE Do not store wood within the outdoor...

Страница 16: ...air flow regulated by a solenoid flows into the firebox through combustion air outlets located on the front sides and the back near the bottom Secondary air is regulated by solenoids that allow air f...

Страница 17: ...stion occurs in the Reaction Chamber where extremely high temperatures aid in complete combustion The chimney creates a draft negative pressure which helps to draw exhaust gases from the furnace 3 Hea...

Страница 18: ...ecessary for the proper operation of the outdoor furnace Ash acts as an insulator keeping the glowing coals in the bottom of the firebox hot enough to restart the fire when needed after being in idle...

Страница 19: ...Bypass Alarm Kit p n 2500153 is installed the alarm is a reminder that the bypass door is open During a cold start it will continue to sound Whenopeningthefireboxdoor thedoorswitchwillshutofftheprima...

Страница 20: ...normal and the moisture will evaporate after the first couple of fuel loads 1 With no heat load draw in the system monitor the operation of the outdoor furnace until the water temperature reaches the...

Страница 21: ...furnace frequently or for extended periods of time with the water temperature below 150 F as this will result in more condensation in the firebox that can lead to excessive corrosion NOTE Operating at...

Страница 22: ...sult in poor heat output and combustion because of restricted airflow CompactedashwillnotfallintotheReactionChamber itwillneedtoberemoved with a shovel 4 Some ash in the bottom and the angled sides of...

Страница 23: ...n loading do not tightly pack wood into the firebox Load the wood so that the combustion air outlets on the side of the firebox do not become blocked or restricted 9 Close and latch the firebox door D...

Страница 24: ...ses condensation the firebox and air channels will not dry NO DRYING Very little radiant heat to dry air channels High humidity Reloading at this level can restrict airflow and create excessive coals...

Страница 25: ...be determined D When new after three months then every six months thereafter F Frequency will vary depending on heat load requirements type of wood used and the moisture content of the wood E Refer to...

Страница 26: ...n the preventive maintenance schedule are intended to serve as a guideline Actual intervals between inspections and maintenance may vary depending on a number of factors including your heat load requi...

Страница 27: ...The wood load should be matched to the heat load MAINTENANCE SECTIONS Refer to the Preventive Maintenance Schedule for the recommended intervals with which to perform these maintenance items 3 1 Wate...

Страница 28: ...free of obstruction Combustion Air Outlets one side of firebox shown same on other side Secondary Air Charge Tube Keep the combustion air outlets open and clear of ash and coals to allow the furnace t...

Страница 29: ...e the Wonder Bar to completely scrape the face of the firebox door frame where the door seal contacts 6 Using the illustration as a reference push the cleaning rod back and forth through the ash in th...

Страница 30: ...r 3 7 Heat Exchangers NOTE Clean the heat exchangers weekly until the interval for your application can be determined Frequency will vary depending on a number of factors including heat load requireme...

Страница 31: ...e the hoe to pull the ash to the front of the furnace then use a small shovel to remove all of the ash and deposits from the Reaction Chamber Take care not to damage the temperature sensor 7 Close the...

Страница 32: ...he hoe to pull the ash to the front of the furnace then use a small shovel to remove all of the ash and deposits from the Reaction Chamber Take care not to damage the temperature sensor NOTE It is ext...

Страница 33: ...s of corrosion are present determine the cause and correct it as soon as possible Refer to the section title Corrosion is Present in the Troubleshooting section 3 A thin tar like creosote layer may fo...

Страница 34: ...all ash and deposits from behind the side air channels Combustion Air Outlets one side of firebox shown same on other side Secondary Air Charge Tube Keep the combustion air outlets open and clear of a...

Страница 35: ...bolts 7 Close and secure the airbox cover Install the outer airbox cover and secure with screws Do not connect power or operate the outdoor furnace with the outer airbox cover removed The outer airbo...

Страница 36: ...wer source Do not proceed without testing that power is disconnected Make sure the power cannot be reconnected while servicing the solenoids i e use lock out tag out 2 Remove the outer airbox cover th...

Страница 37: ...grease 3 15 Complete Firebox Cleaning Procedures The procedures outlined here explain how to thoroughly clean the firebox Reaction Chamber heat exchanger and chimney tee The frequency for performing t...

Страница 38: ...etailed procedures Use the Wonder Bar to completely scrape the areas shown in gray 2 Reaction Chamber 3 Firebox 4 Chimney Tee 5 Heat Exchangers 6 Reaction Chamber Pay special attention to these seams...

Страница 39: ...It is extremely important to clean all the way to the back of the Reaction Chamber To make sure ash is being completely removed mark the hoe handle when the hoe is positioned all the way to the back o...

Страница 40: ...osion Use a wire brush to clean if needed 4 ChimneyTee 1 Remove the chimney inspection cover Clean the chimney outlet and chimney of excessive ash or deposits NOTE The chimney inspection cover must fi...

Страница 41: ...remove the plate remove the acorn nuts Take care not to damage the gasket View Inside Firebox The plate at the back of the firebox can be removed for inspection and cleaning the heat exchangers if nee...

Страница 42: ...plates Remove any ash or deposits from behind the air channel plates in the wall of the firebox 2 Using a screwdriver or similar tool clean out each combustion air outlet in the air channel plates Mak...

Страница 43: ...sing a new test kit The pH test strips and Permanganate Reagent each have a varying shelf life that can affect their accuracy Test kits should be stored in a dry area at room temperature to obtain max...

Страница 44: ...container 2 Dip the pH test strip from the test kit in the water sample Shake excess water off the test strip Compare the color of the test strip to the chart provided to determine pH level 3 If the...

Страница 45: ...he valve when finished The water in the sight gauge valve and tube will drain when the valve is closed CAUTION The water in the sight gauge may be hot Use caution when obtaining a sample 2 If no antif...

Страница 46: ...t but 15 to 30 drops is acceptable One drop of permanganate reagent equals approximately 100 ppm SYSTEM MAINTENANCE The pH and nitrite levels of the water once treated should remain stable as long as...

Страница 47: ...een maintained and corrosion is present in the water jacket The water jacket should be thoroughly flushed and the system refilled with the proper amount of Corrosion Inhibitor Plus added Be sure to te...

Страница 48: ...codes and regulations When performingworkonanapplianceobserveallprecautionsintheliterature tagsandlabels attached to the appliance and other safety precautions that may apply When working with electr...

Страница 49: ...firebox 1 Disconnect power to the outdoor furnace Do not proceed without testing that power is disconnected Make sure the power cannot be reconnected while testing components i e use lock out tag out...

Страница 50: ...d latch assembly 2014 Central Boiler CAUTION The firebox door seal will be damaged or destroyed if it is not installed properly REACTION CHAMBER DOOR SEAL The Reaction Chamber door seal must be in goo...

Страница 51: ...e all the way around the Reaction Chamber door cut the end of the rope about one inch longer than required and press it tightly against the beginning end of the rope 7 Close the Reaction Chamber door...

Страница 52: ...Do not proceed without testing that power is disconnected Make sure the power cannot be reconnected while testing components i e use lock out tag out 2 Remove the outer airbox cover then open the airb...

Страница 53: ...t power to the furnace and test solenoid operation Do not connect power or operate the outdoor furnace with the outer airbox cover removed The outer airbox cover must be installed and secured with scr...

Страница 54: ...ce making sure the alignment pin fits into the alignment hole in the refractory modules THERMOCOUPLE 1 Disconnect power to the outdoor furnace Do not proceed without testing that power is disconnected...

Страница 55: ...he higher the moisture content of the wood being burned the harder it is to maintain the proper coal bed because energy is required to heat the wood and more slowly evaporate boil off the water The la...

Страница 56: ...Reaction Chamber remain unobstructed to allow final combustion to occur It is not designed to be an ash collection area although over time ash will gradually accumulate in the Reaction Chamber If ash...

Страница 57: ...ure Is there creosote and or ash inside the airbox Creosote ash or even coals in the airbox is an indication that the outdoor furnace has not been maintained and or operated properly Especially import...

Страница 58: ...nce section If adding water does not correct the problem contact your Central Boiler dealer 10 Low water temperature for too long a period of time The display on the controller will indicate and the c...

Страница 59: ...flue draft is less than 0 05 in WC 12 45 Pa add more chimney sections After the test fill the hole in the chimney inspection cover with high temp silicone Perform test with bypass closed at normal op...

Страница 60: ...t either add drier smaller pieces of wood first or partially fill with wood to allow time for the coals to restart the fire 5 Water temperature setpoint too low Set the water temperature setpoint high...

Страница 61: ...ems 7 Supply and return lines installed incorrectly Make sure the hot supply line is connected to the correct fitting on the outdoor furnace and heat exchanger 8 Circulation pump s installed backwards...

Страница 62: ...ropriate procedure see Owner Serviceable Items 2014 Central Boiler NOTE Iftheoutdoorfurnaceisoperatedwiththedooropen thefireboxdoorsealmaybedamaged 2 Solenoid and or air regulating disc stuck open or...

Страница 63: ...must not be located below the pump motor If necessary remove the four screws and rotate the pump body 2 Water will not circulate If the system has been drained and refilled or if the system has been o...

Страница 64: ...al under many conditions and is not suggestive of poor combustion or high emissions Opacity is the amount of light which is blocked in an exhaust plume It is a measurement that is usually stated as a...

Страница 65: ...load is low during warm outdoor temperatures for example filling the firebox full with wood can lead to condensation in the firebox When the demand for heat is low add only enough wood to the firebox...

Страница 66: ...pendant l utilisation NE br lez PAS de bois trait de plastique ou de caoutchouc dans la chaudi re Le tirage maximal est indiqu sur la plaque signal tique Respectez TOUJOURS l ensemble des l gislations...

Страница 67: ...63 CLASSIC EDGE OUTDOOR FURNACE OWNER S MANUAL WIRING DIAGRAM SECONDARY SOLENOID FAN PRIMARY SOLENOID...

Страница 68: ...are not covered Parts that are factory installed by Central Boiler but are manufactured by others may be covered by their own manufacturer s warranty and are not covered by this limited warranty excep...

Отзывы: