LSS-2404
27 |
P a g e
Independent Widths (27)
Check the ‘Independent Widths’ box to enable the ability to set a different time for each
individual channel.
When unchecked the Strobe Widths for all 4 channels will be locked to each other; changing one changes them
all.
Independent Channel Strobe Widths per Frame (28)
Check the box to enable the ability to set a different strobe width for every active channel per frame. Further
setting
s are done in the ‘Advanced Settings’.
Advanced (10)
Additional settings such as;
1
Status Level
–
Brightness of the status LED. Ranges from 1-100%. Requires clicking
‘Save to Controller’ for
changes to take effect.
2
Trigger Strobe Period
–
length of time in milliseconds the Status LED blinks when a valid trigger occurs.
Requires clicking
‘Save to Controller’ for changes to take effect.
3
Output Delay
–
Delays when the light flashes for every flash. Maximum delay is 1 millisecond.
4
Startup Delay
–
The LSS will ignore triggers coming into the LSS for the set time.
5
Static IP
–
Sets the IP address of the LSS controller and the GUI software.
6
Update Temperature
–
Displays the temperature the LSS controller is operating at. Temperature will not be
updated until this button is pressed.
7
Individual Strobe Widths
–
Set the strobe width for each active channel per frame.