LSS-2404
6 |
P a g e
Hardware Information
This information is for guidance only. Installers must perform their own risk assessment specific to each
installation. While CCS America Inc. has taken extensive care in the preparations of this advice, CCS America Inc.
accepts no liability for damages of any kind except those required by law. Deliberate acts of endangerment and
vandalism are not covered by this document and must be considered by the installer.
Environmental Considerations
The 2404 does not have an IP rating and must be mounted so that moisture and dirt cannot enter the unit. Free
air can be used as a cooling method.
Information
Limits
Operating Temp range
0
o
–
40
o
C (32
o
–
104
o
F)
Operating Humidity Range 10%
–
80% (non
-
condensing)
Storage Temp
-10
o
–
50
o
C (14
o
–
122
o
F)
Hardware
LSS Controller
Ethernet
–
Connect to the computer
with an ethernet cable.
Lighting Output
–
The M12-5
lighting output connector directly
connects to dedicated CI lights or a
breakout cable for use with almost
any CCS light.
Power Input
–
Connect to 24 VDC
power supply with the polarity as
marked.
Trigger Out
–
Connect the Trigger
Out terminals to the camera’s
trigger input pins per the wiring
section below.
Trigger In
–
Connect the external
system’s trigger to Trigger In to start
the lighting sequence. The trigger
may be any voltage from 3.3 V to 24
VDC. See the Trigger Out section
below for more information.