LSS-2404
28 |
P a g e
GUI Settings
Clear (32)
Pressing ‘Clear’ removes all check boxes in the channel mapping and allows the user to set a new sequence
from
scratch.
Log and Titles (33)
IP
–
LSS static IP address
Name
–
LSS device name
Product
–
LSS product name and firmware version number
PCB
–
LSS PCB info number consisting of 3 parts
ID: Identifies which type of LSS (01=LSS2404, 02=reserved for future model)
REV: LSS PCB revision
MOD: Modification Number
ID
–
Unique processor identification number
Recipe Version
–
Recipe version supported by the GUI. If a different recipe version is loaded from a file, it will
cause an error displayed in a pop-up window.
Temperature
–
Shows the temperature (in Celsius) the LSS is operating at
Log
–
Shows the changes that have been made to the LSS for debugging purposes
Auto Log Size Limit
Automatically checked; sets the maximum size the log can be before clearing. Uncheck if you need to manually
control the size of the log.
Summary
A table of the default values is below. Note
: clicking ‘Test Defaults’
sets the Active settings to these values.
Variable
Default
Trigger Type
One-Shot
Trigger Level
9.6 V
Ground Trigger
unchecked
Executions
1
Frame Time
25 mS
Frame Rate
40 fps
Camera Trigger Width
15 mS
Camera Trigger Voltage 24 V
Strobe Width
20 mS
Independent Widths
Unchecked
Number of Frames
4
Channels
Frame 1; Channel 1
Frame 2; Channel 2
Frame 3; Channel 3
Frame 4; Channel 4