LSS-2404
10 |
P a g e
Connection Requirements
A specification sheet of the LSS is in Appendix A.
Power Supply/Consumption
Specifications
The following specifications are for the LSS-2404 controller.
Information
Limits
Notes
Nominal Input Voltage
12 - 24 VDC
Max allows to work with most
12-24 VDC power supplies
10.8 - 28.8 VDC Maximum
Max Continuous Supply
Current
2.0A /channel
Do not connect lighting that
exceeds these limits
4.0 A total for all channels
Uses common ground power system*
Thermal Fuse**
1.5A PTC per channel
Prevent damage in fault
conditions related to individual
channels
Main Fuse***
7A
Protects all electrical
components from various issues
Power Consumption
5W
Excluding attached lighting and
dependent configuration
* The (-) power supply input, the (-) trigger input, the (-) trigger output and any grounded metal enclosures are
all electrically connected and treated as ground. This must be given proper consideration when making electrical
connections between the control box and other system components. Ensure that all components connected are
capable of having their low side (-) contacts joined and grounded without creating an electrical fault.
**PTC fuses are self-resettable and are designed to limit unsafe currents while allowing constant safe current
levels. Resistance will “reset” automatically when the fault is
removed, and the temperature returns to a safe
level. In the event of a fault condition, remove power and the fault condition (if applicable) and wait five
minutes. Power the LSS-2404 back on to restore operation. The product warranty does not cover any damage
that may have occurred due to improper connection or operation.
***If the main fuse blows the LSS will appear to have no power or indicators. If this occurs the unit is not user
repairable and must be sent in to CCS America for repair.