3827 • U2 3/10
7
AC E
lECtriCAl
S
yStEm
S
ECtion
3
10. Push the spring-loaded generator STOP/START switch, located on the
DC Control Center, to the START position and hold it there until the
generator starts. Release the switch when the generator starts.
If the generator does not start within 10 seconds, release the STOP/
START switch, wait 1 minute, then try to start the generator again.
11. When the generator is running smoothly, switch the Generator circuit
breaker group(s) on the AC Control Center ON. Power is now available
to the other AC circuit breakers on Line 1 and/or Line 2.
12. To turn the generator OFF, push the STOP/START switch to the
STOP position. If you do not intend to use the generator again for at
least a few days, turn the generator battery master disconnect switch to
the OFF position.
Do not inhale generator exhaust. Generator exhaust contains carbon monoxide,
a poisonous gas. Refer to Section 1 - Carbon Monoxide (CO) Warnings for more
information on engine exhaust and carbon monoxide.
Operating AC Equipment
Power to your boat’s AC equipment is controlled by circuit breakers and, in
most cases, individual controls for each component.
Your boat contains two AC circuit breaker panels:
• AC Main Circuit Breaker Groups
• AC Control Center
The circuit breakers on these panels enable you to control the electricity to
either the AC component itself or to the equipment’s controls by switching
the breakers ON or OFF. They also protect the electrical system by
automatically disconnecting the circuit from the power source in the event
of a short or overload. Power is supplied to these two circuit breaker panels
by either a shore power source or the generator.
Never reset a breaker that has automatically tripped without first correcting
the problem. Failure to follow this procedure may create a dangerous
situation.
NOTE:
Sometimes a circuit breaker location is labeled but no circuit breaker is
present. In this case, the component named on the label is an option that is
not installed on your boat.
AC Main Circuit Breaker Groups
When using a shore power source to supply AC power to your boat, the
power is routed through an AC Main circuit breaker group before it enters
the boat. Each shore power cord has its own AC Main circuit breaker
group.
The AC Main circuit breaker groups are located in the aft port cabinet of
the salon. When these circuit breaker groups are ON, power flows to the
AC Control Center. (Refer to page 2 and 8)
https://www.boat-manuals.com/
Содержание 38 Super Sport
Страница 1: ...HIN CVRU2099D010 2010 Version 1 38 Super Sport Owner s Guide https www boat manuals com...
Страница 2: ...https www boat manuals com...
Страница 4: ...https www boat manuals com...
Страница 6: ...https www boat manuals com...
Страница 28: ...16 3827 U2 3 10 Boating Safety Section 1 This page intentionally left blank https www boat manuals com...
Страница 55: ...3827 U2 3 10 15 AC Electrical System Section 3 AC Wiring Schematics A C Schematic https www boat manuals com...
Страница 56: ...16 3827 U2 3 10 AC Electrical System Section 3 This page intentionally left blank https www boat manuals com...
Страница 70: ...14 3827 U2 3 10 Internal Systems Section 4 This page intentionally left blank https www boat manuals com...
Страница 82: ...12 3827 U2 3 10 Propulsion Section 5 This page intentionally left blank https www boat manuals com...
Страница 106: ...14 3827 U2 3 10 Maintenance Section 7 THIS PAGE INTENTIONALLY LEFT BLANK https www boat manuals com...
Страница 116: ...10 3827 U2 3 10 Winterization and Storage Section 8 This page intentionally left blank https www boat manuals com...
Страница 124: ...8 3827 U2 3 10 Warranty and Parts Section 9 Bill of Material https www boat manuals com...
Страница 125: ...3827 U2 3 10 9 Warranty and Parts Section 9 Carver Limited Warranty https www boat manuals com...
Страница 126: ...10 3827 U2 3 10 Warranty and Parts Section 9 This page intentionally left blank https www boat manuals com...