1
7
ENG
“UE
B
A
SIC”
+0300042IE
-
rel
.
1
.
6
-
21
.
11
.
2019
6. STARTING AND USER INTERFACE
steam
production
in
progress
cylinder
fi
lling
in
progress
foam
in
the
cylinder
presence
water
in
the
cylinder
cylinder
water
drain
in
progress
6.4 Keypad
key
function
return
to
the
previous
display
from
the
main
screen:
pressed
for
5
seconds
disables/
enables
the
humidi
fi
er
UP
from
the
main
screen:
display
the
humidi
fi
cation
values
(current
,
conductivity
,....
)
,
see
the
following
paragraph
from
the
list
of
parameters:
circular
navigation
of
the
parameters
and
set
the
values
DOWN from
the
main
screen:
display
the
humidi
fi
cation
values
(current
,
conductivity
,....
)
from
the
list
of
parameters:
circular
navigation
of
the
parameters
and
set
the
values
EN
T
ER
(PRG)
for
2
seconds:
access
the
list
of
parameters
from
the
list
of
parameters:
select
and
con
fi
rm
(like
the
“Enter”
key
on
a
computer
keyboard)
6.5 Main display
T
he
display
on
the
humidi
fi
er
normally
shows
the
current
steam
production
(kg/h
,
basic
display)
.
T
o
display
other
values
,
press
UP
or
DOWN
and
scroll
the
following
list:
•
input
signal
(0
-
100%
,
or
ON/OFF
if
A
0
=
0)
•
access
alarm
log
(HYS
)
(**)
•
set
maximum
steam
production
(parameter
P0)
(*)
•
current
(
A
)
•
conductivity
(μS/cm)
•
cylinder
hour
counter
(h)
T
o
return
to
the
basic
display
,
press
ESC
.
Parameter
C0
(see
chap
.
7)
can
be
used
to
change
the
value
of
the
basic
display
(default:
current
steam
production)
.
(*)
T
o
modify
the
maximum
steam
output
(P0)
press:
•
EN
T
ER
(display:
)
•
UP
or
DOWN
to
set
the
value
percentage
of
production
(from
20
to
100%)
•
EN
T
ER
to
con
fi
rm
the
new
value
Press
ESC
to
return
to
the
main
screen
Parameter
P0
can
also
be
accessed
from
the
list
of
parameters
(see
chap
.
7)
.
(**)
T
o
display
the
alarm
log
(HYS
)
press:
•
EN
T
ER
(the
most
recent
alarm
is
shown)
•
UP
or
DOWN
to
scroll
the
list
of
alarms
in
chronological
order
press
ESC
to
return
to
the
main
screen
T
o
delete
the
list
of
alarms
press
UP
and
DOWN
for
5
seconds
(inside
the
alarm
log)
,
when
the
list
has
been
reset
the
display
will
show
‘res’
.
6.6 Disabling
T
he
humidi
fi
er
can
be
disabled
in
3
di
ff
erent
ways:
•
Opening
contact
M2
.
4
and
M2
.
5
(enable)
:
the
display
shows
C
--
•
From
serial
(see
Chap
.
7
Digital
2)
:
the
display
shows
S
--
•
From
terminal
(see
ESC
button)
:
the
display
shows
t
--
Before
starting
the
humidi
fi
er
,
check:
Ƒ
water
connections:
chap
.
2
.
In
the
event
of
water
leaks
do
not
start
the
humidi
fi
er
before
having
resolved
the
problem;
Ƒ
steam
distribution:
chap
.
3
and
electrical
connections
chap
.
4
.
6.1 Starting
1
1
0
ON
2
if
the
cylinder
is
new
,
run
a
pre
-
wash
cycle
by
pressing
EN
T
ER
+
DOWN
for
5
sec
.
(the
cylinder
is
fi
lled
and
emptied
three
times
,
cleaning
the
inside
walls
from
impurities)
.
A
display
shows
the
symbol
PRE
Cln
6.2 Stopping
1
empty
the
water
in
the
cylinder
to
avoid
stagnation
(see
paragraph
6
.
12
“Manually
drain
the
water
in
the
cylinder”)
.
2
1
0
OFF
6.3 Display
humiSteam
basic
esc
μS/cm
Fig.
6.a
Key:
manually
drain
the
cylinder
(see
paragraph
6
.
6)
power
supply
(green
LED)
humidi
fi
er
operating
(yellow
LED)
Flashing:
steam
production
not
yet
in
steady
operation
Steady:
steam
production
in
steady
operation
alarm
(red
LED
,
not
fl
ashing)
A
larm
activated:
LED
fl
ashing
and
buzzer
active
If
an
alarm
is
active
pressing
ESC
mutes
the
buzzer
and
the
LED
comes
on
steady
,
pressing
ESC
again
resets
the
alarms
(see
Chap
.
8)
conductivity
value
time
in
seconds
instant
current
value
in
A
mperes
real
hour
counter
steam
fl
ow
-
rate
(Imperial
system)
steam
production
as
a
percentage
of
rated
capacity
steam
fl
ow
-
rate
(international
system
,
default)
parameter
programming
in
progress
(parameter
setup)
maintenance
request
(alarm
active)
or
display
alarm
log
(HYS)
on
steady:
external
fan
or
steam
production
active
.
Flashing:
external
fan
or
steam
production
awaiting
start/
stop
3
digits
,
after
999
the
display
shows
to
indicate
1000
(only
three
digits
plus
point
-
between
the
fi
rst
and
the
second
digit
-
are
displayed
)
.
Содержание humiSteam Basic UE001
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 44: ...4 ENG UE BASIC 0300042IE rel 1 6 21 11 2019 ...
Страница 46: ...ENG ...
Страница 83: ...ENG ...