1
2
ENG
“UE
B
A
SIC”
+0300042IE
-
rel
.
1
.
6
-
21
.
11
.
2019
3. STEAM DISTRIBUTION
3.1 CAREL jet distributors (SDPOEM00**)
T
hese
can
be
fi
tted
horizontally
or
vertically
(hole
facing
upwards)
.
See
page
31
for
the
models
of
distributors
.
Assemb
l
y
instructions
(
see
Fig
.
3
.
a
):
•
make
a
series
of
holes
on
the
wall
according
to
the
distributor
drilling
template;
•
insert
the
distributor;
•
fasten
the
fl
ange
using
4
screws
.
31,5
50
50
31,5
50
31,5
31,5
57,5
100
C
D
C
A
A
B
B
Fig.
3.a
Key:
A
.
steam
inlet
B
.
condensate
drain
C
.
steam
outlet
.
the
dimensions
of
the
hole
vary
depending
on
the
models
of
distributor:
model
SDPOEM0000:
hole
made
manually
,
up
to
30
mm
(1
.
2”)
in
diameter);
model
SDPOEM0012:
diameter
of
the
hole
12
mm
(0
.
5”);
model
SDPOEM0022:
diameter
of
the
hole
22
mm
(0
.
9”)
.
D
drilling
template
Note:
if
steam
hoses
with
an
inside
diameter
of
30
mm
(1
.
2”)
are
used
,
remove
the
22
mm
(0
.
9”)
steam
inlet
section
.
3.2 CAREL linear distributors for air ducts
(DP***DR0)
Install
away
from
obstacles
(curves
,
branches
,
changes
in
cross
-
section
,
grills
, fi
lters
,
fans)
.
Minimum
distance
between
the
distributor
and
the
obstacle:
1/1
.
5
m
(3
.
3/4
.
9
ft)
.
Increase
the
distance
if:
•
the
air
speed
increases
in
the
duct
,
•
the
relative
humidity
of
the
air
increases
before
and
after
humidi
fi
cation
,
•
the
turbulence
decreases
.
See
page
33
for
installation
examples
.
Assemb
l
y
instructions
(
see
Fig
.
3
.
b
):
•
make
a
series
of
holes
on
the
wall
according
to
the
distributor
drilling
template
(included
in
the
packaging
with
the
distributor);
•
insert
the
distributor
with
the
steam
holes
facing
upward;
•
fasten
the
fl
ange
using
4
screws
.
A 22
B 10
Y 58
35
X 68
dimensioni in
B
Y
X
A
X
°2
1
2
3
4
5
6
8
7
Fig.
3.b
Key:
1
“L”
-
shaped
mounting
support
(where
featured)
2
fl
ange
gasket
3
steam
inlet
(Ø
A
)
4
condensate
drain
(ØB)
5
screw
diameter
(see
the
instruction
sheet
supplied
with
the
distributor)
6
length
(depending
on
the
model
of
distributor
,
see
par
.
“10
.
5”
page
38)
7
angle
(around
2°)
for
draining
the
condensate
.
8
diameter
of
the
hole
on
the
wall
(ØY)
Dimensions
in
mm
(
in
)
CA
R
EL
l
inear
distributors
DP***D
22
R
0
DP***D
3
0
R
0
DP***D40
R
0
ØA
22
(0
.
9”)
30
(1
.
18”)
40
(1
.
57”)
ØB
10
(0
.
4”)
10
(0
.
4”)
10
(0
.
4”)
ØY
58
(2
.
3”)
68
(2
.
7”)
89
(3
.
5”)
Ø
35
(1
.
4”)
45
(1
.
8”)
60
(2
.
4”)
X
68
(2
.
7”)
77
(3
.
0”)
99
(3
.
9”)
T
ab.
3.a
Important:
1
.
fi
t
the
distributor
at
a
slight
incline
(at
least
2°
,
to
prevent
the
return
of
condensate);
2
.
the
“L”
-
shaped
mounting
support
(see
part
1
Fig
.
3
.
c)
is
supplied
with
steam
distributor
models
from
DP085*
to
DP205*
.
For
shorter
lengths
,
the
support
can
be
supplied
as
an
option
(code
18C478
A
088)
.
3.3 CAREL steam blowers (VSDU0A*, models
UE001 to UE018 only)
Steam
distributors
for
humidi
fi
ers
with
fl
ow
rates
up
to
18
kg/h
(39
.
7
lb/h)
.
Can
be
connected
on
top
of
the
humidi
fi
er
,
or
separately
in
another
location
(see
the
fi
gure
below)
.
A
B
C
D
E
F
G
DIMENSIONS
(m)
A
B
C
D
>0
,
5 >5 ≥2
,
1 >1
DIMENSIONS
(m) E
F
G
>0
,
5 >5 >1
Fig.
3.c
Important:
For
correct
distribution
of
the
steam
,
observe
the
distance
shown
in
the
fi
gure
above
.
Содержание humiSteam Basic UE001
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 44: ...4 ENG UE BASIC 0300042IE rel 1 6 21 11 2019 ...
Страница 46: ...ENG ...
Страница 83: ...ENG ...