4
2
ENG
“UE
B
A
SIC”
+0300042IE
-
rel
.
1
.
6
-
21
.
11
.
2019
Periodical
drain
When
using
water
rich
in
substances
such
as
humus
and
lime
,
a
periodical
drain
cycle
should
be
set
for
the
cylinder
to
avoid
accumulating
residues
.
T
o
enable
the
periodical
drain
,
set
parameter
b1
to
64
.
In
this
way
,
every
24
h
the
humidi
fi
er
will
drain
all
the
stagnant
water
in
the
cylinder
,
and
the
display
will
show
code
“dP”
(periodical
drain)
.
If
the
periodical
drain
is
enabled
,
the
number
of
hours
between
two
periodical
drain
cycles
can
be
set
using
parameter
“bE”
.
Note:
For
the
manual
drain
function
,
see
chap
.
6
,
for
the
mechanical
drain
see
paragraph
9
.
4
.
12.5 Automatic insufficient supply water
management
T
he
humidi
fi
er
checks
whether
there
is
no
supply
water
or
the
fl
ow
-
rate
of
supply
water
is
too
low
,
by
controlling
if
the
current
at
the
electrodes
increases
after
opening
the
fi
ll
solenoid
valve
.
In
this
case
,
the
humidi
fi
er:
•
displays
alarm
“EF”
•
activates
the
alarm
relay
,
•
opens
the
contactor
and
closes
the
fi
ll
solenoid
valve
for
10
minutes
.
A
fter
the
10
minutes
,
the
fi
ll
solenoid
valve
is
opened
,
the
contactor
closed
and
the
phase
current
measured:
if
it
increases
the
alarm
is
deactivated
,
otherwise
the
procedure
is
repeated
.
NO
T
E:
the
alarm
is
reset
automatically
and
is
managed
according
to
the
procedure
described
above
.
12.6 Alarm relay switching
Once
the
operating
hours
corresponding
to
the
cylinder
maintenance
request
have
been
reached
(“CY”
alarms)
,
the
alarm
relay
(if
there
are
no
other
alarms
active)
will
switch
for
10
seconds
every
12
hours
,
until
reaching
the
“Mn”
alarm
.
T
his
function
is
activated
using
parameter
b1
(see
paragraph
11
.
6);
normally
disabled
12.7 Auxiliary contact management (active
fan request)
T
he
auxiliary
contact
can
be
used
to:
-
remote
signalling
of
steam
production
request
(but
not
the
actual
value);
-
activation/deactivation
of
an
external
fan
unit
,
based
on
whether
the
steam
production
request
is
present
.
A
ctivating
this
function
by
parameter
b1
,
the
contact
is
activated
(CLOSED)
during
steam
production
,
with
a
delay
of
A
6
seconds
,
and
deactivated
(OPEN)
with
a
delay
of
A
7
seconds
.
During
A
6
and
A
7
the
symbol
(fan)
will
fl
ash
on
the
display
,
during
activation
the
symbol
(fan)
will
be
on
steady
.
During
the
manual
drain
(see
Chap
.
6
.
12)
the
contact
will
be
deactivated
(always
after
the
delay
A
7)
During
pre
-
wash
(see
Chap
.
6
.
1)
the
contact
be
activated
,
with
the
corresponding
delays
.
12.8 Manual procedure
T
his
procedure
is
used
to
manually
control
the
devices
on
the
humidi
fi
er
.
From
the
main
screen
,
press
the
PRG
button
for
2
seconds
.
Enter
the
password
70
using
UP
or
DOWN
.
T
he
display
will
show
MAn
Press
PRG
.
T
he
display
will
show
tlr
T
hen
scroll
the
various
devices
using
UP
and
DOWN:
-
tlr
=
Contactor
-
drn
=
Drain
pump
-
FiL
=
Fill
SV
-
drt
=
Drain
tempering
SV
(
not
used
)
-
ALr
=
A
larm
relay
-
FAn
=
A
uxiliary
contact
(fan)
Pressing
PRG
from
any
these
options
shows:
ON
if
the
device
is
currently
active
OFF
if
the
device
is
currently
inactive
Press
PRG;
the
display
starts
fl
ashing
Press
UP
or
DOWN
to
modify
the
value
Press
PRG
to
con
fi
rm
.
Press
ESC
to
return
to
the
previous
display
.
N
.
B
. T
HE
MODE
C
A
N
ONLY
BE
EXI
T
ED
USING
T
HE
ESC
BU
TT
ON
FROM
T
HE
M
A
n
DISPL
A
Y
OR
BY
SWI
T
CHING
OFF
T
HE
HUMIDIFIER
.
12.9 LEDs on the control board
T
here
are
three
LEDs
fi
tted
on
the
expansion
board
,
located
above
the
control
board:
Fig.
1
2
.b
Key:
LED
on
board
Symbo
l
on
disp
l
ay
M
eaning
Red
alarm
in
progress
(the
type
of
alarm
can
be
identi
fi
ed
based
on
the
type
of
fl
ashing
,
see
chap
.
8)
Yellow
steam
production
in
progress
(led
always
on
for
100%
production
,
2
blinkng
20%
,
3
blinking
30%
, ...
)
Green
humidi
fi
er
on
T
ab.
1
2
.a
NO
T
E:
T
he
yellow
and
red
LEDs
are
active
only
if
the
display
is
disconnected
.
Содержание humiSteam Basic UE001
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 44: ...4 ENG UE BASIC 0300042IE rel 1 6 21 11 2019 ...
Страница 46: ...ENG ...
Страница 83: ...ENG ...